Appendix C: Scanner Specifications
Site Specifications
AC Power Requirements | 1,750 watts peak |
|
|
|
|
AC Frequency | 50 or 60 Hz |
|
|
|
|
AC Phase | Single |
|
|
|
|
Operating Environment | Room temperature: | 65 to 80° F (18 to 27° C) |
| Relative humidity: | 20 to 70% |
| Ambient light: | less than 1000 lux; no exposure to direct lighting |
| Altitude: | 7000 feet (2134 m) maximum |
|
|
|
Scanner Specifications
Dimensions and Weight | Height: | 15 in. (38,1 cm) |
| |
| Width: | 24 in. (61 cm) |
| |
| Depth: | 30 in. (76,2 cm) |
| |
| Weight: | 120 lbs (54,5 kg) |
| |
| Footprint: | 5 square feet |
| |
|
|
|
| |
Operating and Service | Rear: | 1.5 feet (45,7 cm) for operation, |
| |
Clearances |
| 3 feet (91,4 cm) for service |
| |
| Sides: | 2 feet (60 cm) for operation and service | ||
| Front: | 4 feet (122,9 cm) for operation and service | ||
|
| |||
Scanner Location | The scanner location relative to the host workstation is limited by the SCSI | |||
| interface cable length; if you are using a cable stocked by Kodak, this | |||
| distance is 2 meters or less. Longer cables are not supported for use with | |||
| the scanner. The scanner must be the only SCSI device attached to the | |||
| host computer. |
|
| |
| The scanner should be located on a table that: | |||
| • is stable |
|
| |
| • can support approximately 120 lbs (54,5 kg) | |||
| • is at least 30 in. (76,2 cm) long x 30 in. (76,2 cm) wide | |||
|
| |||
Power Consumption | Power Consumption: 425 watts maximum; 400 watts typical | |||
and Thermal Load | Thermal Load: | 1325 BTU operating; 1230 BTU standby | ||
|
|
|
| |
AC Voltage and Current | 100 V AC/50 Hz | 4.2 amps operating; | 3.9 amps standby | |
Draw | 100 V AC/60 Hz | 4.1 amps operating; | 3.85 amps standby | |
| 120 V AC/50 Hz | 3.5 amps operating; | 3.2 amps standby | |
| 200 V AC/60 Hz | 2.0 amps operating; | 1.9 amps standby | |
| 200 V AC/50 Hz | 2.0 amps operating; | 1.85 amps standby | |
| 230 V AC/60 Hz | 1.8 amps operating; | 1.7 amps standby | |
| 250 V AC/50 Hz | 1.75 amps operating; | 1.65 amps standby | |
|
|
|
|
|
May 2002 |