Toshiba IK-HD1 Shutter Mode Level PEAK/AVE Speed Area Manual Synchro Scan, 0DH 0EH, Auto, 9CH

Page 8

11.ADDRESS & DATA (1st byte=05H,53H)

*: don’t care

Item

SHUTTER

MODE

LEVEL

PEAK/AVE

SPEED

AREA

MANUAL

SYNCHRO

SCAN

Address

01H

03H

04H

05H

06H

0DH

0EH

 

Data

 

 

Action

 

 

 

 

 

 

H

 

L

 

 

 

 

 

 

 

 

**H

 

00H

AUTO

Sets the SHUTTER MODE and EXT TRIG mode.

 

 

 

 

AUTO:Auto shutter

 

 

01H

MANU

MANU:Manual mode

 

 

 

 

SS:Synchronous scan mode

 

 

02H

SS

 

 

 

 

 

 

 

**H

 

9CH

-100

Adjusts the automatic shutter level.

 

 

Level Low

 

 

 

00H

00

If the high level is selected, the value increases.

 

 

If the low level is selected, the value decreases.

 

 

64H

100

Level High

 

 

 

 

 

 

**H

 

00H

00:10

Adjusts the ratio between peak and average value in the automatic shutter mode.

 

 

00:Average only (01 to 09) : The bigger the value is, the higher the ratio is.

 

 

0AH

10:00

10:Peak only

 

 

 

 

 

 

**H

 

00H

1

Adjusts the automatic shutter response speed.

 

 

The bigger the value is, the faster the response is.

 

 

13H

20

 

 

 

 

 

 

 

**H

 

00H

PRESET A

Selects the available picture area in the automatic shutter mode..

 

 

 

 

PRESET A,B,C,D,E: Specified range

 

 

01H

PRESET B

 

 

 

 

USER:User setting range (Setting area is available)

 

 

02H

PRESET C

 

 

 

 

 

 

 

 

03H

PRESET D

 

 

 

 

 

 

 

 

 

 

04H

PRESET E

 

 

 

 

 

 

 

**H

 

00H

OFF

Sets a shutter speed in manual mode.

 

 

 

 

 

 

 

 

01H

1/100S

 

 

 

 

 

 

 

 

 

 

02H

1/125S

 

 

 

 

 

 

 

 

 

 

03H

1/250S

 

 

 

 

 

 

 

 

 

 

04H

1/500S

 

 

 

 

 

 

 

 

 

 

05H

1/1000S

 

 

 

 

 

 

 

 

 

 

06H

1/3000S

 

 

 

 

 

 

 

 

 

 

07H

1/5000S

 

 

 

 

 

 

 

 

 

 

08H

1/10000S

 

 

 

 

 

 

 

 

 

 

09H

1/30000S

 

 

 

 

 

 

 

 

 

 

0AH

1/50000S

 

 

 

 

 

 

 

0001H

 

 

001/1125H

Sets a shutter time every time a synchronization scan is turned off or every hour of

 

 

data setting.

 

0230H

 

 

560/1125H

001H/1125H~560/1125H:The shutter speed can be set by the 1H.

 

 

 

 

(1H)

(560H)

 

 

 

 

 

 

Image 8
Contents RS-232C communication specifications for IK-HD1C Communication procedure Command code PC to camera ) Memory Data Read REQUEST(FF Address FF FF) )MEMORY Data Read REQUEST(05 Address FF FF))MEMORY Data Write REQUEST(53 Address Datal DATAH) FFH Error Data PresetNormal Address Datal DatahCtemp High Ctemp LOWLevel High Level LOW.ASHD Auto Shading SHD Limit Level High Level LOW SHD NG Not AvalableShutter Mode Level PEAK/AVE Speed Area Manual Synchro Scan Preset aPreset B Preset C0231H Gain Mode Auto MAX Manu White Balance Temp Paint Area AWBATW F6HFF9CH White Gain Balance ATW Paint AWB R Data Read AWB B Data3AH 3BH 3CH A0H A1H Process Gamma ON/OFF Dtlgain .PED F9H0FH Matrix Matrix ON/OFF HUE GainF1H Matrix 5AH 5BH 5CHFC00H 03FFHPR/PB SETFile a File BFile C File DGain Read KEY Lock ReadAuto Read KEY Lock onIndex ShutterWhite Balance Process