Bowens BW7631, BW7630 Connection Order, Display Indications, Switch on the Travel-Pak

Page 6

Connection Order

1

2

3

4

Switch off the Travel-Pak.

Connect Esprit Gemini(s).

Fit Dummy Socket if required.

Switch the Esprit Gemini to Position II.

Display Indications

The indicators flashing usually indicates normal charging.

The following are only displayed in fault conditions.

STEADY INDICATOR LONGER THAN 20 SECONDS [Condition: Travel-Pak unable to supply charge]

Reason

Suggested action

Dummy plug not fitted in unused socket.

Fit plug or connect a second Flash Head.

Thermal cut-out initiated

Wait for Travel-Pak to cool.

 

or

ALTERNATE FLASHING INDICATORS

[Condition: - Battery Voltage Too Low Wait 5mins for Auto Recovery]

Reason

Suggested action

Battery too low for operation

1. Wait for battery voltage to recover slightly

 

2.

Charge Battery (See Instructions).

 

3.

Fit Ext Battery (See Instructions).

The unit may be brought back sooner than 5mins by cycling the power switch, Travel-Pak should not be operated in this condition for longer than necessary.

5

Switch on the Travel-Pak.

FAST DOUBLE BLINK BOTH INDICATORS

[Condition: - Power Saving Mode]

Reason

Power Save after approx 10mins of low activity

Suggested action

1.Change Either Head Selector Switch.

2.Change Charge Mode Fast/Slow.

3.Turn off then back on to reset Travel-Pak.

It is recommended not to leave your Travel-Pak for long periods of time, to wake up the unit change one of the monoblock power switched on either connected head or change the charge rate Fast/Slow switch. The Travel-Pak will recheck connected heads and resume charging again.

6

www.bowens.co.uk

www.bowens.co.uk

7

Image 6
Contents Travel-Pak Travel-Pak+Table of Contents Specifications AccessoriesTypical Flashes Contents of CartonSafety Notes IntroductionControl Panel Guide Fault Finding Carry Bag Removal/FittingConnecting Compatible Flash Heads General QuestionsSingle Esprit Gemini Connection Connection Order Switch on the Travel-PakCondition Power Saving Mode Display Indications