Page - 4 | Operator Manual – SRA Series Amplifiers | |
|
|
|
Important Safety
Instructions – 2
Introduction - 3
The SRA Series - 4
Protection
Physical Description - 5
Installation - 6
Operation - 8
Troubleshooting - 9
Spec Table - 10
Dimensions - 11
Warranty - 12
The SRA Series
The series provides a power range of 75 to 150 watts per channel at 4 ohms
| Stereo |
| Mono Bridged |
| |
Model | 8 |
| 4 | 8 |
|
40 W |
| 75 W | 150 W |
| |
40 W |
| 75 W | 150 W |
| |
80 W |
| 150 W | 300 W |
| |
80 W |
| 150 W | 300 W |
|
•Input connections are via
•Output connectors are screw terminal strips.
•Rear panel switches include: selectable High Pass Filters, Gain and Operation Mode.
Protection
Output
DC output protection - The amplifier is switched off if more than 2 volts of dc is present on the output. The amplifier will automatically restart after 5 seconds (if no fault remains). The protect LED is lit as well as the clip LED of the affected channel(s).
Main supply rail overvoltage protection - The amplifier is switched off if the main supply rails have too high of a voltage. The amplifier will automatically restart after 5 seconds (if no fault remains). The protect LED is lit as well as the clip LED of the affected channel(s).
Chassis internal temperature monitoring - The amplifier is switched off when the internal ambient temp reaches 70º C. The amplifier will again switch on when the internal ambient temp reaches 55º C. The protect LED is lit as well as the clip LED of ALL channels.
Inrush limiting - The
Mains fuse - There is a 5 amp time delay fuse.
Copyright© 2006 – Ashly Audio Inc.