Atlas Sound CP400 user service CH-2

Page 13

CP400 & CP700 COMMERCIAL POWER AMPLIFIER

OWNER'S MANUAL

Bridge Mono Transformer Coupled Output Wiring for 140V/200V Output Operation The amplifier can be configured to drive 140V and 200V speaker lines.

Please observe all necessary safety precautions as the potential for electric shock at the speaker terminals is present.

With the amplifier turned off, move the rear mounted selector switch to the “Bridge” position and connect the input signal to channel 1. Connect your speaker load across the “+” terminals of both output terminals as follows:

140V Operation - Connect the positive lead of the speaker load to the channel 1 70V positive “+” terminal, the negative speaker lead connects to the channel 2 70V positive “+”

terminal. Connect a suitable jumper wire between the two terminals labeled “0”. Consult your local codes to determine if Class I wiring is required (Figure 11).

200V Operation - Connect the positive lead of the speaker load to the channel 1 100V positive “+” terminal, the negative speaker lead connects to the channel 2 100V positive “+” terminal. Connect a suitable jumper wire between the two terminals labeled “0”. Consult your local codes to determine if Class I wiring is required (Figure 12).

Caution: A high voltage potential exists across the two “+” speaker terminals when operating in any Bridge Mode application!

To 140V speaker load

CH-18, 4, and 2 Ohms

 

AUDIO TRANSFORMER CH-1

D I R . O U T P U T +

-

0

70

100 I S O L . O U T P U T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

-

+

 

-

+

 

 

 

 

 

 

 

70V

 

 

 

25V

 

 

 

 

 

 

 

 

BRIDGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MONO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

100V

+

 

 

 

 

 

CH-28, 4, and 2 Ohms

 

 

CH-2

 

AUDIO TRANSFORMER

D I R . O U T P U T +

-

0

70

100 I S O L . O U T P U T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

-

+

 

-

+

 

 

 

 

 

 

 

70V

 

 

 

25V

 

 

 

 

 

 

 

 

BRIDGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MONO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

100V

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note Jumper

Figure 11

Specifications are subject to change without notice

AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •

TELEPHONE: (800) 876-3333

FAX: (800) 765-3435

©2008 ATLAS SOUND LP

Printed in U.S.A.

ATS002102 RevD 2/08

PP

13

Image 13
Contents CP400 & CP700 Commercial Power Amplifier CP400 & CP700 Commercial Power AmplifierCP400 & CP700 Commercial Power Amplifier Table of Contents Features CP400 & CP700 Commercial Power Amplifier IntroductionApplications Protect LED Indicators Power SwitchSignal Status LED Indicator Front Panel DescriptionRear Panel Description 10. CH1/CH2, Low Impedance Speaker Outputs Stereo/Parallel/Bridge Switch11. CH1/CH2, 25/70.7/100V Speaker Outputs Calculating Constant Voltage LoadsBalanced Inputs Input WiringUnbalanced Input Low Impedance Direct Coupled Output Stereo Speaker Output WiringLow Impedance Direct Coupled Output Parallel Mono 25V, 70.7V, and 100V Transformer Output Wiring Bridge Mono Configuration Direct Coupled25V 70.7V100V CH-2 To 200V speaker load Direct Power Out Protection Circuits CP400 & CP700 Commercial Power Amplifier SpecificationsLimited Warranty