in the space exposed by removal of the cover using four
TRANSFORMER
V (yellow preferred) to the upper left (viewed from terminal side) terminal of switch S4; from pin T (blue preferred) to the bottom left (viewed from terminal side) terminal of switch S4; and from pin S (red preferred) to the positive (red dot) terminal of capacitor C14.
Solder a length of
Transformer | Part | Part Terminal |
Lead Color | Connection | Designation |
Red | 28V Terminal | GND |
| Strip (TS1) |
|
Black | 70V Terminal | 70V |
Yellow | Strip (TS2) | CT |
Green |
| COM |
Blue | 70V Slide | Right Center |
| Switch (S4) | Terminal |
FIGURE 16. 70-VOLT CONVERSION:
TRANSFORMER MOUNTING
Remove the white lead from pin H on the Main Circuit board and fasten it to pin Won the Filter Circuit board. Re- move the yellowlblack lead from pin J on the Main Circuit board and fasten it to pin Y o n the Filter Circuit board. Cut a length of
CAUTION
Be careful not to damage board or adjacent compo- nents when soldering.
Run the soldered wire roughly parallel to the long edge of the Main Circuit board to the main wiring harness and along the harness to the
Cut three lengths of
The Amplifier conversion is now complete. Perform a dc balance adjustment as described previously in this section. Reassemble the Amplifier and return it to service.
SERVICE ILLUSTRATIONS
The pages that follow contain parts locating drawings and an overall Circuit Diagram. The parts locating drawings are of the Main and Filter Circuit boards. Foil circuit paths are shown as shaded areas on the drawings. The Circuit Diagram shows all printed circuit board and chassis- mounted parts.
GUARANTEE
This Shure product is guaranteed in normal use to be free from electrical and mechanical defects for a period of one year from date of purchase. Please retain proof of purchase date. This guarantee includes all parts and labor. This guarantee is in lieu of any and all other guar- antees or warranties, express or implied, and there shall be no recovery for any consequential or incidental damages.
SHIPPING INSTRUCTIONS
Carefully repack the unit and return it prepaid to: Shure Brothers Incorporated Attention: Service Department
1501 West Shure Drive Arlington Heights, Illinois 60004
If outside the United States, return the unit to your dealer or Authorized Shure Service Center for repair. The unit will be returned to you prepaid.