Altinex MT113-102/103 manual Description of Commands

Page 9

MULTI-TASKER

7.2 DESCRIPTION OF COMMANDS

Each command consists of three parts: function, card ID, and unit ID. [Function, Card ID, Unit ID]

Example:

[VERC3U2] VER = Function C3 = Card ID U2 = Unit ID

For detailed information regarding function, see each command description.

Card ID is an assigned value from 1 to 19, which represents the number of slots. Card ID 0 (C0) is used for the controller (see user’s guide for the MT100-100). Changing the position of a card will significantly affect the commands recorded on software definitions or a third party control system.

Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to 0, then each command can be used without Ui (use command [SETU0]; see user’s guide for the MT100- 100).

Example:

[VERC3]: for unit ID zero

[VERC3Ui]: for unit ID other than zero

[VERC3]: equivalent to [VERC3U0]

1. [VERCnUi]

This command receives the software version and card type for the MT113-102/103card. Cn = card ID number (n = # from 1 to 19)

Ui = Unit ID (i = # from 0 to 9) (refer to the MT100-100 user’s guide for explanation)

Example:

If one MT113-102card is in slot #2.

To send command [VERC2], the Multi-Tasker™ Enclosure will return:

[MT113-102 VER: 690-0133-007 C02]

2. [CnUi]

This command receives the status of the card. Command Format: [CnUi]

Cn = card id (n = 1 to 19)

9

Ui = unit id (i = from 0 to 9) (refer to the MT100- 100 user’s guide for explanation)

Example:

If one MT109-102card is in slot #2 of unit 3 with input 1 ON:

To send command [C2U3], the Multi-Tasker™ Enclosure will return feedback information about card status, which will display all current settings:

VOLIN1:16

VOLIN2:16

VOLIN3:32

VOLOUT:12

BASS:8

TREBLE:14

LOUDNESS:ON

If there is no card in slot #2 of unit 3, sending the [C2U3] command will not return any feedback.

3. [CnS]

This command is to save card status such as ON/OFF, IN/OUT, and volume control where applicable.

4. [SELmCnUi]

This command sets path to adjust the individual volume level for single card. Command Format: [SELmCnUi] [–] [–] [–] [–] or [+] [+] [+] [+]

m = Input number (m = 1 to 3)

n = Card ID number (n = slot # from 1 to 19) i = Unit ID number (i = 0 to 9)

+= increases volume. (maximum of 15 levels for audio).

– = decreases volume. (maximum of 15 levels for audio).

Example:

If the status of audio card 5 of unit zero is as follows:

VOLIN1:16

VOLIN2:16

VOLIN3:32

VOLOUT:12

BASS:8

TREBLE:14

LOUDNESS:ON

9

Image 9
Contents MT113-102/103 Precautions / Safety Warnings Cleaning Precautions / Safety WarningsGeneral FCC / CE NoticeMechanical Technical SpecificationsDescription of MT113-102/103 Application Diagrams Application DiagramBlock Diagrams Internal View of MT113-102/103 Operation Installing Your MT113-102/103RS-232 Control 1 RS-232 InterfaceDescription of Commands SLOCnUi SELmGkUiVOLmAyCnUi VOLmAyGkUiVOLOmAYGkUi VOLOAyCnUiSELBCnUi SELBGkUiVBLyGkUi VBLyCnUiSELTCnUi SELTGkUiLOD0CnUi VTLYGkUiLOD1CnUi LOD1GkUiRdxx GkUiWrxxyy WRCn…GkUiLED is not on Troubleshooting GuideNo Sound Sound DistortionAltinex Policy Limited Warranty / Return Policy