16.1 | 16 |
3.Place your subject so that it fills the rectangular area in the center of the viewfinder. This shaded portion is the light measuring area of the camera’s silicon photocell and is 12% of the field of view.
4.Turn the meter mode selector to the desired mode. Then lightly press the shutter button halfway to turn on the meter.
The meter needle should be outside of the exposure warning zones. If it is in either zone, turn the shutter dial until the meter needle moves out of the zone.
5.For correct exposure, turn the lens’ aperture ring until the center of the aper- ture needle aligns with the meter needle. The diameter of the circle is equiv- alent to one f/stop, and exposure adjustment is possible in
one f/stop
one half f/stop
Notes:
•The aperture needle moves only between the minimum and maximum aper- tures of the lens in use.
•The meter does not operate with the shutter dial on ”B” or ”S”.r