Sony DCR-TRV130ERMT-814 service manual Self-diagnosis Code Table

Page 6

4.

Self-diagnosis Code Table

 

Self-diagnosis Code

 

 

 

 

 

 

 

 

 

by:

Block

Detailed

Symptom/State

Correction

Repaired

Function

Code

 

 

 

 

 

 

 

 

 

 

 

 

C

0

4

0

0

Non-standard battery is used.

Use the InfoLITHIUM battery.

 

 

 

 

 

 

 

C

2

1

0

0

Condensation.

Remove the cassette, and insert it again after one hour.

 

 

 

 

 

 

 

C

2

2

0

0

Video head is dirty.

Clean with the optional cleaning cassette.

 

 

 

 

 

 

 

C

3

1

1

0

LOAD direction. Loading does not

Load the tape again, and perform operations from the beginning.

complete within specified time

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3

1

1

1

UNLOAD direction. Loading does not

Load the tape again, and perform operations from the beginning.

complete within specified time

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3

1

2

0

T reel side tape slacking when unloading.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

2

1

S reel side tape slacking when unloading.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

2

2

T reel fault.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

2

3

S reel fault.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

3

0

FG fault when starting capstan.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

3

1

FG fault during normal capstan operations.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

4

0

FG fault when starting drum.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

4

1

PG fault when starting drum.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

4

2

FG fault during normal drum operations.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

4

3

PG fault during normal drum operations.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

1

4

4

Phase fault during normal drum operations.

Load the tape again, and perform operations from the beginning.

 

 

 

 

 

 

 

C

3

2

1

0

LOAD direction loading motor time-

Remove the battery or power cable, connect, and perform

out.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

1

1

UNLOAD direction loading motor

Remove the battery or power cable, connect, and perform

time-out.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

2

0

T reel side tape slacking when

Remove the battery or power cable, connect, and perform

unloading.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

2

1

S reel side tape slacking when

Remove the battery or power cable, connect, and perform

unloading.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

2

2

T reel fault.

Remove the battery or power cable, connect, and perform

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

2

3

S reel fault.

Remove the battery or power cable, connect, and perform

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

3

0

FG fault when starting capstan.

Remove the battery or power cable, connect, and perform

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

3

1

FG fault during normal capstan

Remove the battery or power cable, connect, and perform

operations.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

4

0

FG fault when starting drum.

Remove the battery or power cable, connect, and perform

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

4

1

PG fault when starting drum.

Remove the battery or power cable, connect, and perform

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

4

2

FG fault during normal drum

Remove the battery or power cable, connect, and perform

operations.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

4

3

PG fault during normal drum

Remove the battery or power cable, connect, and perform

operations.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

C

3

2

4

4

Phase fault during normal drum

Remove the battery or power cable, connect, and perform

operations.

operations from the beginning.

 

 

 

 

 

 

 

 

 

 

 

 

— 6 —

Image 6
Contents Specifications DCR-TRV130EOther accessories Checking supplied accessoriesSELF-DIAGNOSIS Function Table of ContentsService Note Main PartsService Note Switching of Backup No Display MethodEnd of Display Self-diagnosis Code Table Inspect the lens block focus reset sensor Pin qs of CN1551 DCR-TRV130E Main Parts Disassembly Video Light LCD Section PD-131 BoardFront Panel Section MI-041 Board Cabinet L SectionCabinet R SECTION, Control Switch Block CF-1000 Installation EVF Section VF-129 BoardBattery Panel Section Battery Terminal Board Lens SectionVC-256 Board Mechanism DeckRemoving the Hinge Assembly Hinge SectionExploded Views Overall Section5868 CB a113 103 109 107 108 110 EVF Section112 114 105 102104157 154 163 162161 160 159 153 158155 152 154 152 151Cabinet R Section 204 205 209 203 201 202 207 208201 206 254 253 261 262 252 266 251 265 264 B LCD Section259 260 258 257 256 255 263General DCR-TRV130E Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Sony Corporation Revision History