Process RA-4 Cycle—Average Utilization
This cycle is appropriate for processors with average
Solution/ | Time* | Temperature | |||
Replenishment | |||||
Step | min:sec | °C (°F) | Rate | ||
|
|
|
| mL/m2 (mL/ft2) | |
EKTACOLOR |
|
|
|
| |
PRIME SP |
|
|
| 108 (10) | |
Developer |
|
|
|
| |
Replenisher† |
| 37.8 ± | 0.3 |
| |
or | 0:45 |
| |||
(100.0 ± | 0.5) |
| |||
EKTACOLOR |
|
| |||
|
|
|
| ||
PRIME |
|
|
| 161 (15) | |
Developer |
|
|
|
| |
Replenisher |
|
|
|
| |
|
|
|
|
| |
EKTACOLOR |
|
|
|
| |
PRIME | 0:45 | 30 to 36 | 108 (10) | ||
(86 to 97) | |||||
|
| ||||
Replenisher |
|
|
|
| |
|
|
|
|
| |
EKTACOLOR |
| 30 to 37 |
| ||
PRIME | 1:30 | 248 (23) | |||
Stabilizer and | (86 to 99) | ||||
|
| ||||
Replenisher‡ |
|
|
|
| |
Dry | As | Not over |
| ||
needed | 96 (205) |
| |||
|
|
* Immersion time plus crossover time to the next tank. For best results, use the recommended times with crossover times of 6 seconds or less.
†This developer may not yet be available in your country. If not, use EKTACOLOR PRIME Developer Replenisher in a processor with
average utilization.
‡Use four
If your minilab uses a
Process RA-4 Cycle—High Utilization
This cycle is appropriate for processors with high
Solution/ | Time* | Temperature | |||
Replenishment | |||||
Step | min:sec | °C (°F) | Rate | ||
|
|
|
| mL/m2 (mL/ft2) | |
EKTACOLOR |
|
|
|
| |
PRIME SP |
|
|
|
| |
Developer |
|
|
|
| |
Replenisher† |
|
|
|
| |
or | 0:45 | 37.0 ± | 0.3 | 108 (10) | |
EKTACOLOR | (100.0 ± | 0.5) | |||
|
| ||||
PRIME |
|
|
|
| |
Developer |
|
|
|
| |
Replenisher |
|
|
|
| |
LORR |
|
|
|
| |
|
|
|
|
| |
EKTACOLOR |
|
|
|
| |
RA 100 | 0:45 | 30 to 36 | 54 (5) | ||
(86 to 97) | |||||
and |
|
| |||
|
|
|
| ||
Replenisher‡ |
|
|
|
| |
EKTACOLOR |
| 30 to 37 |
| ||
PRIME | 1:30 | 248 (23) | |||
Stabilizer and | (86 to 99) | ||||
|
| ||||
Replenisher§ |
|
|
|
| |
Dry | As | Not over |
| ||
needed | 96 (205) |
| |||
|
| ||||
|
|
|
|
|
* Immersion time plus crossover time to the next tank. For best results, use the recommended times with crossover times of 6 seconds or less.
† This developer may not yet be available in your country. If not, use EKTACOLOR PRIME Developer Replenisher LORR in a processor with high utilization.
‡ This product will be renamed KODAK EKTACOLOR PRIME
§Use four
If your minilab uses a
Choosing the Right Chemicals for Your Minilab • | 5 |