Kodak C-41RA manual More Information

Page 8

Choosing the Right Chemicals for Your Minilab

KODAK EKTACOLOR PRIME Developer Replenisher

LORR

If new EKTACOLOR PRIME SP Developer Replenisher is not yet available in your region, use this developer if your minilab consistently operates at high utilization, i.e., a developer tank turnover occurs at least once every two weeks.

Available in sizes to prepare 10 litres and 25 gallons (two 12.5-gallon mixes) of replenisher solution.

KODAK EKTACOLOR PRIME Developer Regenerator

If new EKTACOLOR PRIME SP Developer Replenisher is not yet available in your region, your can use this regenerator to regenerate and reuse EKTACOLOR PRIME Developer overflow.

Available in sizes to prepare 10 litres and 25 gallons of replenisher solution from developer overflow.

KODAK EKTACOLOR RA Developer Replenisher RT

If your minilab takes longer than four weeks for a tank turnover, use this developer.

Available in sizes to prepare 5 and 10 litres and 25 gallons.

KODAK EKTACOLOR RA Developer Starter

To make developer tank solutions, mix this starter with KODAK EKTACOLOR PRIME SP Developer Replenisher, EKTACOLOR PRIME Developer Replenisher, EKTACOLOR PRIME Developer Replenisher LORR, or EKTACOLOR RA Developer Replenisher RT according to the directions on the starter label.

KODAK EKTACOLOR PRIME Bleach-Fix Replenisher

Use this bleach-fix if you use EKTACOLOR PRIME SP or PRIME Developer Replenisher. The replenishment rate with this bleach-fix is 50 percent lower than the rate for EKTACOLOR RA Bleach-Fix and Replenisher.

Available in sizes to prepare 10 litres and 12.5 gallons of solution.

KODAK EKTACOLOR RA 100 Bleach-Fix and Replenisher

You can use this bleach-fix if your processor has a tank turnover at least every four weeks. The replenishment rate is

75percent lower than that of EKTACOLOR RA Bleach-Fix. This product will be renamed KODAK EKTACOLOR PRIME Bleach-Fix Replenisher LORR.

Available in sizes to prepare 5 litres and 5 gallons of solution.

KODAK EKTACOLOR RA Bleach-Fix and Replenisher

If it takes more than four weeks to turn over the bleach-fix tank solution, use this replenisher. Dilute this concentrate to prepare a tank or replenisher solution.

Available in sizes to prepare 5 and 10 litres and 25 gallons of solution.

KODAK EKTACOLOR PRIME Stabilizer and Replenisher

Use this stabilizer in place of a final wash in washless minilabs.

Available in sizes to prepare 5 and 10 litres and 12.5 gallons of solution.

MORE INFORMATION

For the latest version of technical support publications for

KODAK Products, visit Kodak on-line at:

http://www.kodak.com

The Material Safety Data Sheets for these products are

available on the Kodak web site:

www.kodak.com/go/MSDS

Many technical support publications for

KODAK Products can be sent to your fax machine

from the Kodak Information Center. Call:

U.S. 1-800-242-2424, Ext. 33 / Canada 1-800-295-5531

—Available 24 hours a day, 7 days a week—

If you have questions about KODAK Products, call Kodak. In the U.S.A.:

1-800-242-2424, Monday–Friday

9 a.m.–7 p.m. (Eastern time) In Canada:

1-800-465-6325, Monday–Friday

8 a.m.–5 p.m. (Eastern time)

Consumer Imaging

EASTMAN KODAK COMPANY ROCHESTER, NY 14650

Choosing the Right Chemicals for

Kodak, Advantix, Ektacolor, Ektacolor SM, Flexicolor,

Major Revision 4-00

Your Minilab

Flexicolor SM, Gold, Max, Prime, and Royal are trademarks.

Printed in U.S.A.

KODAK Publication No. J-36

 

 

CAT 849 8800

Image 8
Contents Choosing a Film Process April 2000 J-36Process C-41RA Process C-41BProcess C-41RA Cycle Starting-Point Replenishment Rates Process C-41RAProcess C-41 Monitoring Your Film ProcessStarting-Point Replenishment Rates Process C-41B Process C-41 CycleChoosing a Paper Process Processor UtilizationProcess RA-4 Cycle-Average Utilization Process RA-4 Cycle-High UtilizationSolution Ft2 Ft† Process RA-4 Cycle-Low UtilizationMonitoring Your Paper Process Current Replenishment RateKodak Chemicals for Your Film Processor Kodak Chemicals for Your Paper ProcessorMore Information