TURNUP & TROUBLESHOOTING GUIDE

PRICING AND AVAILABILITY 800.827.0807 TECHNICAL SUPPORT 800.726.8663 RETURN FOR REPAIR 256.963.8722 www.adtran.com

61221445L1-22B

HDSL4 LOOP SPECIFICATIONS

FOR OPTIMUM OPERATION

NOTE: The H4TU-Cs P/N 1221401L6, 1221403L6, 1221404L6 support only one H4R in the HDSL4 circuit.

HDSL4 circuit containing no H4Rs will reach up to 16 kft on the local loop (24 AWG)

HDSL4 circuit containing one H4R will reach up to 16 kft on the first segment and 15 kft on the second segment (24 AWG).

HDSL4 circuit containing two H4Rs will reach to 13.5 kft on the first segment, 14 kft on the second segment, and 15 kft on the third segment (24 AWG). *

NOTE: Refer to the H4TU-C or H4TU-R Installation and Maintenance Practice, Section HDSL4, Deployment Guidelines, for other loop parameters including Insertion Loss, Pulse Attenuation, and Resistance Budgets for span powering

*This is one example of a circuit with 2 H4Rs. Other loop length configurations are possible in compliance with loop resistance restraints. Refer to the H4R Installation and Maintenance Practice, Section HDSL4 Deployment Guidelines, for other loop parameters including Insertion Loss, Pulse Attenuation, and Resistance Budgets for span powering.

UNIT RESISTANCE

Measurements are with no power applied

The H4R Tip-to-Ring resistance is approximately 6 for each pair.

COMPLIANCE

This product complies with UL 60950, third edition. It is intended for

installation in restricted access locations only and in equipment with a Type “B” or “E” installation code. Ensure chassis ground is properly connected.

Code

Input

Output

Power Code (PC)

C

C

Telecommunication Code (TC)

X

X

Installation Code (IC)

A

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN’s U.S. and Canada Carrier Networks Equipment Warranty

(P/N 60000087-10): call (877) 457-5007, faxback Document 414.

H4TU-C

VMDF

H4R1

H4R2

H4TU-R

 

 

 

 

 

 

 

 

 

 

 

 

 

First Segment

 

Second Segment

 

Third Segment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

239 H4R Capacity Guidelines for ADTRAN Housings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PART No.

Description

CLEI CODE

Slot

Stub

H4R Capacity

Material

 

 

 

 

 

 

 

Above

Below

 

 

 

 

 

 

 

 

 

Ground

Ground

 

 

1150027L1

239/439 Housing

DDMOABA1MA

4

Air

4

4

Stainless/Poly

1150027L2

239/439 Housing

DDMOBBA1MA

4

Gel

4

4

Stainless/Poly

1152010L3

239/439 Housing

DDMOBAE1RA

2

Gel

2

2

Polymer

1152010L4

239/439 Housing

DDMOAAE1RA

2

Air

2

2

Polymer

1150057L1

Universal Housing

DDMODAO1RA

4

Air

4

4

Stainless Steel

1150057L2

Universal Housing

DDMOCAO1RA

4

Gel

4

4

Stainless Steel

1150058L1

Universal Housing

DDMOEEO1RA

8

Air

8

8

Stainless Steel

1150058L2

Universal Housing

DDMOFE01RA

8

Gel

8

8

Stainless Steel

1190816L1

16-Slot BG Housing

DDMOES0IRA

16

Air

16

16

Stainless Steel

1190816L2

16-Slot AG Housing

DDMOFS0IRA

16

Gel

16

16

Stainless Steel

1190816L3

16-Slot AG Housing

DDMOMS01RA

16

Air

16

16

Stainless Steel

 

 

 

 

 

 

 

 

 

239 H4R Capacity Guidelines for Other Housings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manufacturer Description

Manufacturer’s Part Number

Slot

Stub

H4R Capacity

Material

 

 

 

 

 

 

 

Above

Below

 

 

 

 

 

 

 

 

 

Ground

Ground

 

 

ADC

Radiator II

SPX-HRXC-30-AG-016GT

16

Air

16

16

Stainless Steel

ADC

Radiator II

SPX-HRXC-30-BG-016GT

16

Gel

16

16

Stainless Steel

ADC

Radiator

SPX-HRXC-30-B1

8

Air

8

8

Stainless Steel

Circa Telecom

HDSL-12A

760005

 

12

Air

12

12

Polymer

Circa Telecom

HDSL-12B

760006

 

12

Gel

12

12

Polymer

Arris

Keptel® Inter Link809

RF809A3-XXX or RF809B3-XXX

12

Gel

8 1

N/A

Polymer

Arris

Keptel® Inter Link818/819

RF819A1 or RF819A2

25

Air

12 2

16 3, 4

Polymer

Arris

Keptel® Inter Link818/819

RF819B1 or RF819B2

25

Gel

12 2

16 3, 4

Polymer

Arris

Keptel® Inter Link

RF820AX or

 

 

 

 

 

 

 

 

820 Family

RF820BX

2-8

Air

Full

Full

Polymer

Arris

Keptel® Inter Link

RF820AX or

 

 

 

 

 

 

 

 

820 Family

RF820BX

2-8

Gel

Full

Full

Polymer

1The recommended 8 slot assignments for above ground installation are as follows: 1, 3, 4, 6, 7, 9, 10, 12.

2The recommended 12 slot assignments for above ground installation are as follows: Chamber 1: 1, 4, 7, 8, 11, 14 and Chamber 2: 15, 17, 19, 20, 23, 25

3For 16 slot use, the ambient air temperature measured 1 ft away and parallel to the housing should not exceed 115ºF (46.1ºC).

4The recommended 16 slot assignments for below ground installation are as follows: Chamber 1: 1, 3, 5, 7, 8, 10, 12, 14 and Chamber 2: 15, 16, 18, 19, 20, 22, 24, 25

Page 2
Image 2
ADTRAN 239 H4R manual HDSL4 Loop Specifications For Optimum Operation, Unit Resistance, Compliance, Warranty