Wiring Specifications
The VSC4S is designed to connect to the VSM4SK, or VSUC4SK video door answering system using category 5 or category 6 cable.
• Maximum cable length: 250 ft
IMPORTANT: NuTone cannot be responsible for improper system operation that results from inter- ference generated by light dimmers, fluorescent lighting fixtures, and similar electrical products. Such interference must be corrected at the source.
TO HELP REDUCE THIS INTERFERENCE, ALL WIRING CONNECTED TO THE CAMERA MUST BE PLACED AT LEAST 12 INCHES FROM ANY A.C. POWER WIRING. AVOID RUNNING INTERCOM WIRES PARALLEL TO A.C. POWER WIRING.
Connecting and Mounting the Camera
Frame Construction (New Construction)
1.At the camera location, attach a single gang wall box (pur- chase locally) to the wall stud. Normal mounting height is 60" from the top of the wall box to the floor.
2.Run the category 5 or category 6 cable from the VSM4SK or VSUC4SK location to the camera location (250 ft maxi- mum length).
3.Run the cable into the box. Leave approx 12" of extra cable in the box.
4.After the finished wall surface has been applied, strip approximately 2" of outer protective jacket from the catego- ry 5, or category 6 cable.
5.Separate and strip approx 1/2" of insulation from each of the eight wires in the cable. Twist the following cables together:
•OR and OR/WH
•GR and GR/WH
•BL and BL/WH
•BR and BR/WH
6.Remove the plastic back frame and rubber gasket from the camera. Position the back frame and gasket over wire and attach to the wall box using (2) #6 x 3/4" machine screws (supplied). Level the back frame before tightening screws completely.
7.Attach each of the twisted pair of wires to the corresponding screw terminal on the back of the camera. Tighten each screw securely.
8.Dress extra cable into wall box and position the camera, starting at the top onto the plastic back frame.
9.Fully seat the camera into the back frame and secure the camera with 4mm camera attachment screw (supplied) thru the bottom of the back frame and camera.
Important: If camera is exposed to outside elements, caulk should be added to the top and sides of the camera at the wall surface. Do not caulk bottom surface.
Existing Construction
1a. At the camera location, a single gang wall box can be cut into the existing wall surface (maybe required by local code). Normal height is 58" from center of the hole to the floor.
1b. At the camera location, drill a 3/8" hole into the wall directly next to a wall stud. Normal mounting height is 58" from the center of the hole to the floor.
2.Run the category 5 or category 6 cable from the VSM4SK or VSUC4SK location to the camera location (250 ft maximum length).
3.Run the cable thru the hole (or into the box if used). Leave approx 12" of extra cable protruding thru the hole (or box if used).
4.Strip approx. 2" of outer protective jacket from the category 5, or category 6 cable.
5.Separate and strip approx 1/2" of insulation from each of the eight wires in the cable. Twist the following cables
together:
•OR and OR/WH
•GR and GR/WH
•BL and BL/WH
•BR and BR/WH
6.Remove the plastic back frame and rubber gasket from the camera. Position the back frame and gasket over wire and attach into the wall stud using (2) #6 x 1 1/4" screws (supplied) (or two #
7.Attach each of the twisted pair of wires to the corresponding screw terminal on the
back of the camera. Tighten each screw securely.
6