Connecting alarm input/output terminal
Alarm input terminal
Connect infrared sensor, door sensor, metal sensor or sensor of manual switch and the like.
●To prevent noise from entering the internal circuit, supply
●Do not supply voltage.
●Can be set via menu whether to set to alarm when the contact is short (MAKE), or when the contact is open (BREAK). (A Pg. 37)
●Supply such that the alarm signal continues for more than 200 ms. The recognition of alarm signal may not be guaranteed if less than 200 ms.
IN
GND
CLASS 2 ONLY(U TYPE) |
| SEE INSTRUCTION | ||
ISOLATED POWER ONLY(E TYPE) | ||||
|
|
| MANUAL | |
|
|
|
| POWER |
+ | - | DC12V d | INT | LL |
1 | 2 | AC24V H |
|
|
MENU
SET
VIDEO OUT
SELECTOR
Alarm output terminal
Connect to alarm devices such as alarm, indicator, light or buzzer.
●As it is an open type collector output insulated by photocoupler, it will turn on during alarm.
●This terminal has polarity. Make sure to connect such as the voltage of + terminal is higher than - terminal. It will be damaged if reverse voltage is supplied.