JVC GY-DV550 How to Use Skin Tone Detail Cont’d, Skin Tone Detail function, Status

Page 47

 

13. FEATURES OF THE CAMERA SECTION

13-6

How to Use Skin Tone Detail

The contour emphasis in the skin color areas of the video signal can be controlled and made to appear gentle and smooth.

13. FEATURES OF THE CAMERA SECTION

13-6

How to Use Skin Tone Detail (Cont’d)

 

 Confirming the color tone area adjusted with

 

 

OPERATE

2. ~ 8.

1. STATUS button

SHUTTER dial

 

 

SHUTTER

 

 

MENU

 

- - - CAMERA MENU - - -

 

SCENE F I L E

: A

 

VF D I SP L AY

MENU . .

Cursor

OPERAT I ON MENU . .

PROCESS MENU . .

 

F I L E STORE . .

 

SETUP MENU . .

 

T I ME DATE

MENU . .

 

EX I T

 

 Setting the Color and Range of the Skin Tone Detail Function

1. Press the STATUS button for about 1 second to display the CAMERA MENU screen.

2. Turn the SHUTTER dial downward to align the cursor (>) with the PROCESS item. Then press the SHUTTER dial in the direction of the arrow to display the PROCESS screen.

3. Turn the SHUTTER dial downward to align the cursor (>) with the ADVANCED PROCESS item. Then press the SHUTTER dial in the direction of the arrow to display the ADVANCED PROCESS screen.

4. Turn the SHUTTER dial downward to align the cursor (>) with the SKIN COLOR ADJUST item. Then press the SHUTTER dial in the direction of the arrow to display the SKIN COLOR ADJUST screen.

The frame shown on the screen indicates the detection area of the skin tone detail function.

 

 

 

the Skin Tone Detail function

 

 

 

When the ZEBRA switch on the front section is pressed to the

 

 

 

“SKIN AREA” side, the color tone areas adjusted with Skin Tone

PUSH

 

OFF ZEBRA

Detail are displayed in the viewfinder.

 

 

ON

SKIN

AUTO

 

AREA

WHITE

 

 

 

 

 

ACCU

 

 

 

FOCUS

 

 

VTR AUDIO

TAKE

 

 

LEVEL CH-1

 

ZEBRA switch

 

- - - PROCESS - - -

SCENE F I L E A

MASTER B L ACK

: NORMA L

DETA I L

: NORMA L

DT L . V / H BA L

: NORMA L

DT L . FREQUENCY

: LOW

SK I N D T L D E T E C T : OFF

V RESOLUT I ON

: NORMA L

ADVANCED PROCESS . .

PAGE BACK

 

PROCESS screen

- - - ADVANCED

PROCESS - - -

5. When the cursor (>) is aligned with the SKIN COLOR DET.

 

item, the SHUTTER dial is pressed in the direction of the

 

arrow and EXECUTE selected, the skin color detection

 

mode is activated.

6.

Shoot so that the area with the color that you want to detect

 

is brought within the detection area frame. To decide on the

 

color for the detection, press the SHUTTER dial to set SKIN

 

COLOR DET. to STOP.

 

The areas recognized by the skin tone detail function

 

 

appear with superimposed zebra patterns.

 

If the color is not recognized as a color that the skin tone

ACCU - FOCUS

G

F

I

SD

B

"SD" display

Using the Skin Tone Detail Function

To use the skin tone detail function set on the SKIN COLOR ADJUST screen, set the SKIN DTL DETECT item on the PROCESS menu to “ON”.

While the Skin Tone Detail function operates, the “SD” indicator is displayed on the Status 0 and Status 1 screen in the viewfinder.

 

SCENE F I L E

A

COLOR MATR I X

 

: ON

GAMMA

 

 

 

: NORMA L

SK I N

COLOR AD J US T . .

PAGE BACK

 

 

ADVANCED PROCESS screen

- -

SK I N COLOR

AD J UST - -

Detection

 

 

 

 

area

 

 

 

 

 

 

 

 

 

 

ERORR

 

SK I N

COLOR DET .

 

: EXECU TE

SK I N COLOR RANGE

 

: NORMA L

PAGE

BACK

 

 

SKIN COLOR ADJUST screen

detail function works with, "ERROR" is displayed on the

screen.

7. If you want to change the color range recognized by the skin tone detail function, perform the following operations. Set the SKIN COLOR DET. item to EXECUTE. 1 Turn the SHUTTER dial to align the cursor (>) with SKIN COLOR RANGE, and then press the SHUTTER dial in the direction of the arrow.

 

a The area with the setting value starts blinking, and

 

the value can now be changed.

2

Turn the SHUTTER dial up or down to widen or narrow the

 

color range.

Adjust the range while observing the zebra patterns. 3 To decide the color range, press the SHUTTER dial in

the direction of the arrow.

a The setting value stops blinking but remains lit.

8. To stop the SKIN COLOR ADJUST operation, align the cursor (>) with BACK PAGE and press the SHUTTER dial in the direction of the arrow.

STATUS 0

SKIN COLOR ADJUST screen

91

92

Image 47
Contents SC961000 E Model For Customer UseSC96999 U Model Cable Length Port Cable LengthPort Interference by one or more of the following measures InformationLiterature accompanying the appliance Time Code Operation Main Unit ConfigurationMain Features IntroductionPeriodical Maintenance Routine and Periodical MaintenancePrecautions for Proper Use Head CleaningFront Section Battery Pack to be UsedCharacteristic CCD Phenomena Videocassette to be UsedRight Side Section Camera Setting SectionFront Section Cont’d Right Side Section Contd VCR Setting SectionRight Side Section Cont’d VCR Display Section Time Code Generator setting switchesRight Side Section Contd Left Side Section Adapter Section Top SectionRear Section Rear Section Contd Counter Display ContentsVF-P115B 1.5-Inch Viewfinder optionalLens optional S14 x 7.3B12 Status Screens Indications in Viewfinder ContdViewfinder Screen Display Status Time/Date Display  Alarm Message DisplayIndication Contents Indication Indication ContentsBasic System Indication in Viewfinder ContdProvided Microphone Attaching the Microphone optionalAttaching the Viewfinder optional Attaching the Zoom Lens optionalAttaching the 4-inch Viewfinder Optional Lithium battery CR2032 How to Install the Lithium Battery  How to Remove Lithium BatteriesAttaching a Flat Shape Type Battery Pack Power SupplyBattery Pack Operation Contd Battery Pack OperationPrecautions for the Battery Pack Using AN ANTON-BAUER Battery PackLoading the Cassette Turning the Power onPreparations Cassette Loading and UnloadingFilter Setting the Date and TimeCamera Settings Screen Size 43/169 aspect ratio Mode SelectionBrightness and contrast adjustment External Monitor AdjustmentViewfinder Adjustment White Balance Adjustment White Balance AdjustmentLine Switch Settings of the VCR SectionOn the front section Manual Adjustment of Audio Input Level How to use the audio input level control Alarm Monitor Monitor SelectBasic Recording Operation Contd About the Quick REC Start ModeShooting Operation Basic Recording OperationVTR switch setting VCR Save ModeIf Unit is Left in Record-Pause Standby Mode Recording from the Save modeModel Recording External Video SignalsSettings GENLOCK/AUXRecording with an External VCR Contd Playback ModePlayback Procedure Displaying Time Code Presetting and Recording of Time CodeTime Code Operation Fast-Forward, RewindTC OUT Genlock AUX Monitor OUT Presetting Users BIT Data Set the related VCR Setup Menus Advance PresetReproducing Time Codes Setting Mark Mode Explanation of the S.S.F. FunctionMark Mode 10-2 How to Use the S.S.F. Function10-4 Resetting S.S.F. Data CUE Mode10-5 Connecting a Video Component with DV ConnectorWriting S.S.F. Data to Tape Outputting S.S.F. DataVCR Setup Menu Configuration Setup MenuConnecting a PC VCR Setup MenuVCR Setup Menu Contents VCR Setup Menu ContdOn Screen 12-1 VCR Setup Menu ContdCamera Menu Screen Flow Time CodeVF Display Screen 12-3 How to Select from the Camera Menu12-5 Operation Screen12-6 Process Screen Storage Operation Skin Color Adjust Screen12-7 Advanced Process Screen File Manage ScreenTime Date screen Setup ScreenER dial Reset OperationSetting procedure WHT.BAL selector switch13-2 Iris Brightness AdjustmentAdjustment of Lens Iris Zebra Pattern Display During Manual Adjustment Automatic Setting Contents 13-4 Gain Sensitivity AdjustmentGain Switching Switch FunctionsSkin Tone Detail function 13-6 How to Use Skin Tone Detail13-6 How to Use Skin Tone Detail Cont’d  Using the Skin Tone Detail FunctionUnavailable functions Zoom Focus SC Coarse SC Fine Phase Gamma Title Title SETSC Coarse SC Fine Phase ConnectionFunction of Internal Switches Connecting the camera remote control unit Cont’dTroubleshooting Alarm IndicationsAlarm Indications Contd Troubleshooting ContdRemedy 14-1 Troubleshooting ContdTroubles with Error Code Outputs Error Code Error Details GY-DV550 OperationFor servicing Hour Meter Troubles Without Error Code OutputsSymptoms Power cannot be switched on Hour Meter Display103U Specifications14-3 External Dimensions unit mm Specifications