JVC LYT0002-0N4B specifications Counter R/M Power, Tape Counter, Insert editing, Indicator

Page 42
NOTES:
When Insert Editing is performed with the LCD monitor fully opened, the original audio will be heard from the speaker.
After step 5, Retake (pg. 18) can be performed. The tape may stop slightly before or after the
designated end point, and noise bars may appear. Neither indicates a defect in the unit.
Only video signal is recorded in the Insert Editing mode.
Press STOP.
7
5 Press and hold INSERT, and without releasing INSERT, press and release PAUSE. The Insert mode is engaged, and the scene the camcorder is aimed at appears on the screen.
BEGIN INSERT EDITING
6 Press START/STOP. When the counter reaches “0:00:00”, editing stops automatically and the camcorder enters the Insert-Pause mode.
END INSERT EDITING
RESET COUNTER
Play back the tape, locate the Edit-out point and press PAUSE on the camcorder or the remote control.
FIND EDIT-OUT POINT
Set the Power switch to “PLAY”.
1
2
3 Press and hold COUNTER R/M for more than
2 seconds to reset the tape counter, then press again for less than 1 second and make sure “M” appears in the LCD monitor or the viewfinder.
Insert Editing
You can record a new scene into a previously recorded tape, replacing a section of the original recording with minimal picture distortion at the in- and out-points. The original audio remains unchanged.
NOTE:
Use the RM-V704U or RM-V700U remote control unit to perform this procedure.
SELECT MODE

42EN USINGREMOTECONTROLUNIT (cont.)

COUNTER R/M

POWER

 

M-1:23:45

 

 

Tape Counter

 

 

 

 

 

 

FIND EDIT-IN POINT

 

 

 

 

Insert editing

 

 

 

 

 

 

Press REW to go a little beyond the beginning of the

 

 

 

 

indicator

 

 

 

 

 

4 scene you want to replace, press PLAY to view the

 

 

 

 

 

 

 

 

 

 

 

recorded tape, and press PAUSE exactly at the Edit-

 

 

 

 

 

LCD monitor or

 

 

 

in point where the new scene should start.

 

 

 

 

viewfinder

 

 

 

ENGAGE INSERT EDITING MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START/STOP

REW

PLAY

PAUSE

INSERT

RM-V704U or RM-V700U (provided)

Image 42
Contents GR-AXM30 Dear Customer It is recommended that youThis unit is produced to comply with Standard IEC Publ Rechargeable Batteries Hagemeyer NZ Limited P.O. Box 100589 Auckland Phone 09415Zoom-in Zoom-out AC Power Adapter Cassette Adapter C-P7U Battery PackLithium Battery Shoulder Strap DC Cord Charger AA-V11EA BN-V12UPLAY/PAUSE BATT. ReleaseEject Push Monitor Open Stop REWAttach Battery Pack PowerSupply Power Detach Battery PackCar Battery Charger/Adapter BH-V3E optional Charge markerInsert Battery Close CoverClose the compartment cover until it clicks in place Start Clock Operation Close MenuNear Menu FAR Set Power to Camera Tape length indicator Recording Mode SettingSET Recording Mode LCD monitor or viewfinder Recording mode indicatorLoading/Unloading a Cassette Viewfinder Adjustment Tripod Mounting Adjust LengthShoulder Strap Attachment Attach StrapLoad a Cassette Enter RECORD-STANDBY ModePower Start ShootingTape remaining time indicator Stop RecordingStart/Stop button Display button Lens Cover SwitchStart/Stop Power indicator Before the following steps, perform pgJournalistic shooting Self-recordingBrightness control Purpose FeatureRetake R/F OperationLight OFF/AUTO/ON Video LightSET Video Light JVC dealer for replacing the video lightProgramme AE With Special Effects Brighten Image Restore Initial SettingExposure Control Darken ImageRelease Focus Lock FocusingLock Focus Near FARPower zoom lever Program AE select dial FAR NearFader WideInstant Titles Character GeneratorSelect Display SELPress SEL. repeatedly until DISP. appears Adjust White Balance Manual White Balance Adjustment M.W.BAdjust Focus Select White BalanceMenu Make SettingDetailed camcorder settings This camcorder is equipped with an easy-to-useNorm Interval Timer OFFGain UP OFFMenu FAR Near 1S 1/2S 1/4S OFF 5MIN 1MIN 30S 15S OFFAnimation Time-LapseRewind or Fast-forward the tape Speaker volume controlAdjust Volume PlaybackFF Stop REW PLAY/PAUSE Counter R/M Feature Connect Camcorder to VCR Connect Camcorder to TVPlay Back on Connected VCR Cassette AdapterInsert Cassette in Adapter Remove Cassette from AdapterVCR Recording deck Operate the VCR Random Assemble Editing R.A.EditSET Remote to Operate VCR Connect toPrepare VCR Access R.A. Edit Counter DisplayPrepare Camcorder Register Beginning of SceneOUT in OUT Begin Automatic EditingEND Automatic Editing Edited Tape VCR StopReplace Battery Holder Installing The BatteryPull OUT Battery Holder RM-V704U or RM-V700U providedRemote sensor Index Code Marking Interval Timer IndicatorRec Time Indicator LCD monitor or viewfinder START/STOP Viss INT. Time REC TimeTape Counter Counter R/M PowerIndicator Insert editingREW Play Audio dubbing indicatorMicrophone DUBSet to Power OFF BATT. Release Push EjectRemove Symptom Viewfinder Power source This may occur when the surface or the edge of the LCDAn error number i.e. E03 appears Lens Cover Warning indicator may blink whenFocus Indicator Tape End Display ................................ pg48EN Bright Dial Pg.17 Volume Dial Power Switch Pg.15 Recording Mode SP/LP SelectCounter R Reset/M Memory Tally Lamp Power On IndicatorDate/Time Setting Auto Mode Lock Mode Auto Mode Release ModeClock Lithium Battery Connection to a VCR/TV Dioptre Adjust Electronic Fog Filter ModeDo not modify or disassemble Use only specified chargers Do not use near flammable or explosive materialsDo not burn Charging 10C to 35C Operation 0C to 40CMake sure the cassette bears the VHS-C mark Places of over 50CDirect sunlight A closed car in summer Near a heater Serious malfunctioning Cleaning the video headsAbout moisture condensation Dust and dirt on video headsDimensions X 25 H Weight Approx g Accessory Detection, timerControlled Dimensions X 42 H Weight Approx g Adjustment Auto/Manual adjustmentPage GR-AXM30