A. WV-CL920 (120 V AC 60Hz)

1.Plug the AC power cord (supplied as standard accessory) into the AC Inlet Socket.

2.Connect the AC power cord to a 120 V AC 60 Hz

outlet.

Notes:

Connect the power cord firmly.

The power cord should be long enough for pan- ning and tilting.

If the cable is too short, the power cord plug may be pulled off the camera when the camera pans or tilts.

B.WV-CL924 (12 V DC/24 V AC)

The WV-CL924 has an AC/DC compatible input termi- nal. The 12 V DC or 24 V AC power supply cord can be connected to this terminal. The camera detects the power source automatically.

Resistance of copper wire [at 20°C (68°F)]

Copper wire

#24

#22

#20

#18

size (AWG)

(0.22 mm2)

(0.33 mm2)

(0.52 mm2)

(0.83 mm2)

 

 

 

 

 

Resistance

0.078

0.050

0.030

0.018

/m

 

 

 

 

 

 

 

 

 

Resistance

0.026

0.017

0.010

0.006

/ft

 

 

 

 

 

 

 

 

 

Calculation of maximum cable length between camera and power supply.

10.8V DC VA (R x 0.42 x L) 16 V DC

L : Cable length (m)

R : Resistance of copper wire (/m)

VA : DC output voltage of power supply unit

L standard =

VA

12

(m)

 

 

 

 

 

0.42 x R

1.12 V DC Power Supply Connect the power cord to the AC/DC compatible input terminal on the rear panel of the camera.

DC 12V

AC 24V

IN

IN

 

1

 

2

 

GND

12 V DC

(10.8 V - 16 V)

L minimum =

VA

16

(m)

 

 

 

0.42 x R

L maximum =

VA

10.5

(m)

 

 

 

 

0.42 x R

-9-

Image 9
Contents WV-CL924 Bol, within an equilateral triangle, is Contents Preface FeaturesClean the CCD faceplate with care PrecautionsDo not attempt to disassemble the camera Handle the camera with careWV-CL924 Major Operating Controls and Their FunctionsFlange-back Adjusting Ring FB Auto Iris Lens Connector0Gen-lock Termination Switch Hi-Z, G/L 75Ω 1Gen-lock Input Connector GEN-LOCK4AC/DC Compatible Input Terminal DC 12V IN/AC 24V 3Power Cord SocketConnections WV-CL920 120 V AC 60HzWV-CL924 12 V DC/24 V AC Recommended wire gauge sizes for 24 V AC line AC Power SupplyInstallation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the top Installation of CameraCamera Setup Menu SetupATW1 ATW2 AWC Press and hold down for 2 seconds or more Opening the Setup MenuAll Reset Operation Setup OperationImportant Notice Editing the CAM SET UP MenuCamera Identification Camera ID Setting Setting ProceduresTo edit the Camera ID To enter a blank space in the Camera IDLight Control Setting ALC/ELC To erase all characters in the editing areaTo determine the display position of the Camera ID Back Light Compensation Back Light Comp ALC Mode with Preset onALC Mode with Preset OFF Blinking Gain Control Setting AGC ON/OFF Shutter Speed Setting ShutterElectronic Sensitivity Enhancement Sens UP Important Notices Synchronization Setting SyncVBS Gen-lock Mode Extvbs Page Line-lock Sync Mode LL VS Gen-lock Mode ExtvsPhase Coarse White Balance Setting White BAL Auto-Tracing White Balance Mode ATWATW1 Auto Tracing White Balance Select AWC → Manual Fine Adjustment for AWC ATWMotion Detector Setting Motion DET Lens Drive Lens Drive Signal SelectionSpecial Menu Special Burst BW Prevention of Blooming and Smear To reset to the factory settingsAGC SpecificationsPage Standard Accessories Optional Accessories Panasonic Canada Inc