Controls and their functions

Left Side Panel

Operation panel

; < 7 8 9 : GH I

1 2 3 4 5 6 D E F

BREAKER

AC OUT(200VA)

MAIN

ALARM

 

RESET

 

CCU

 

 

 

 

 

> = < ?@ ;

:

= ? @ B C J K L

 

 

 

 

> A

:Cable clamp

This is used to clamp the optical fiber cable from the CCU.

;Optical fiber connector

OPT FIBER connector (EDW.3K.93C.CLC made by LEMO)

Pin No.

Function

Polarity

Signal flow

1

Optical fiber

 

CAM#CCU

2

Optical fibe

 

CCU#CAM

3

Control wire, hot

+

CAM!#CCU

4

Control wire, cold

CAM!#CCU

5

AC 240V live

+

CCU#CAM

6

AC 240V neutral

CCU#CAM

1VF power switch [VF POWER]

This is used to set the viewfinder’s power to ON or OFF. When it is lighted, the viewfinder’s power is OFF.

2Front tally ON/OFF switch [FRONT TALLY]

This is used set the viewfinder and lens tally lamp to ON or OFF. When the lamp is lighted, the tally lamp is OFF.

3CENTER marker switch [CENTER MARKER] This is used to set the center marker to ON or OFF.

4CURSOR switch

This is used to set the cursor on the viewfinder screen to ON or OFF. When it is lighted, the cursor is OFF.

<AC outlet

An AC output of up to 200 VA can be supplied to this outlet.

=AC outlet circuit-breaker

This is the circuit-breaker for the AC outlet. If the AC output load is too high and the circuit breaker has been tripped, reduce the load, and then reset the circuit breaker by pressing the circuit breaker button.

>Power main circuit breaker

This is the main circuit-breaker for the unit's power supply. If the circuit breaker has been tripped by an overcurrent or for some other reason, check the cause, take the appropriate measures to remedy the problem, and then reset the circuit breaker by pressing the circuit breaker button.

?AC OUTLET reset switch

This cuts off the AC output when it drops below the minimum voltage that can be supplied. When this has happened, the outlet can be reset by pressing this reset switch without turning off the camera's power.

@AC OUT alarm display

This lights when the AC output voltage range exceeds 10%.

5Cursor memory switch 1

If this switch is held down while the cursor switch is ON, the current cursor status is stored in the memory. If the cursor switch is set to ON after the cursor memory switch 1 has been pressed, the cursor which was stored in the memory by the cursor memory switch 1 can be called.

6Cursor memory switch 2

If this switch is held down while the cursor switch is ON, the current cursor status is stored in the memory. If the cursor switch is set to ON after the cursor memory switch 2 has been pressed, the cursor which was stored in the memory by the cursor memory switch 2 can be called.

7H-POSI control [H-POSI]

This is used to adjust the horizontal position of the cursor.

8V-POSI control [V-POSI]

This is used to adjust the vertical position of the cursor.

9Width control [WIDTH]

This is used to adjust the width of the cursor.

:Height control [HEIGHT]

This is used to adjust the height of the cursor.

6

Image 6
Contents Model AK-HBU931P Safety precautions FCC NoteContents Operating precautionsOverview Controls and their functions Front PanelBottom Panel Right Side Panel Left Side Panel Operation panel ND filter indicators 1 to Marker switch= ND filter selector switch ND ? Local switch LocalMounting the camera Mounting methodsMounting the lens Detaching the camera from the camera mounting baseConnections External dimension drawings Specifications AccessoriesVQT0B67