Axis Communications Q604 manual Multi-Connector Cable sold separately, Function Pin Specifications

Page 15

AXIS Q604 Series

Multi-Connector Cable (sold separately)

When connecting external equipment to the Axis product, a multi-connector cable (available from Axis) is required in order to maintain the product’s IP rating. The multi-connector cable can be purchased from your Axis reseller.

Connect the multi-connector cable to the product’s multi-connector. To locate the multi-connector, see Hardware Overview on page 10. The cable provides the following connectors:

Power connector - 3-pin terminal block used for power input. See image below. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a rated output power limited to 100 W or a rated output current limited to 5 A.

Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).

Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier . A stereo connector must be used for the audio out.

I/O terminal connector - Use with external devices in combination with, for example, tampering alarms, motion detection, event triggering, time lapse recording and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:

Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under System Options > Port & Devices > Port Status) if the alarm device is activated.

Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under System Options > Port & Devices > Port Status).

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1

 

 

 

 

 

 

DC output

2

Can be used to power auxiliary equipment.

3.3 V DC

 

 

Note: This pin can only be used as power

Max load =

 

 

out.

250 mA

 

 

 

 

15

Image 15
Contents Axis Q604 Series Equipment Modifications Legal ConsiderationsLiability Intellectual Property RightsLearn More SupportPage Other Message Levels Hazard LevelsTransportation BatteryDome Cover Axis Q604 SeriesPage Installation Steps Package ContentsOptional Accessories Hardware Overview Dome Cover Camera Unit Drop Ceiling Mount Hard Ceiling MountNetwork Connector Midspan LED IndicatorsConnectors and Buttons LED IndicatorsControl Button Audio ConnectorPower Button SD Card SlotFunction Pin Specifications Multi-Connector Cable sold separatelyConfigurable Digital input Connect to pin 1 to Operating Conditions SpecificationsPower Consumption Product Classification Temperature HumidityInstall the Hardware ConnectorsReplace the Dome Cover Install an SD Card Drop Ceiling Mount Ceiling tile Hole diameter 225 mm 8.9 Axis Q604 Series Bracket Mount sold separately Axis Q604 Series Install the Midspan Further Information Access the Product Reset to Factory Default SettingsWarranty Information Page Errata Page Page Installation Guide