Axis Communications Q1635 manual Power Connector, Audio Connector, RS485/RS422 Connector

Page 14

AXIS Q1635 Network Camera

NOTICE

Due to local regulations or the environmental and electrical conditions in which the product is to be used, a shielded network cable (STP) may be appropriate or required. All cables connecting the product to the network and that are routed outdoors or in demanding electrical environments shall be intended for their specific use. Make sure that the network devices are installed in accordance with the manufacturer’s instructions. For information about regulatory requirements, see Electromagnetic Compatibility (EMC) on page 2 .

I/O Connector

Use with external devices in combination with, for example, tampering alarms, motion detection, event triggering, time lapse recording and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:

Digital output – For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.

Digital input – An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under System Options > Ports & Devices).

Power Connector

2-pin terminal block for power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.

Mini DC connector. Use the supplied adapter.

Audio Connector

The Axis product has the following audio connectors:

Audio in (pink) – 3.5 mm input for a mono microphone, or a line-in mono signal.

Audio out (green) – 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier . A stereo connector must be used for audio out.

RS485/RS422 Connector

Two terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment such as PTZ devices.

14

Image 14
Contents Axis Q1635 Network Camera Intellectual Property Rights Legal ConsiderationsLiability Equipment ModificationsContact Information Page Hazard Levels Other Message LevelsBattery TransportationAxis Q1635 Network Camera Page Optional Accessories Installation StepsPackage Contents Hardware Overview Axis Q1635 Network Camera LED Indicators Color IndicationNetwork Connector Buzzer LensAudio Connector ConnectorPower Connector RS485/RS422 ConnectorSD Card Slot SpecificationsProduct Temperature Humidity Control ButtonFunction Pin Specifications Activated, floating unconnected when Drain, 100 mASetup example Audio Output RS485/422 ConnectorAudio Input Function PinInstall the Hardware Access the Product Adjust FocusFocus Assistant Replace the Lens Reset to Factory Default Settings Further InformationWarranty Information Installation Guide