Axis Communications M3007P user manual Camera Orientation, Set Power Line Frequency, Live View

Page 9

AXIS M3007–P

Access the Product

The default administrator user name root is permanent and cannot be deleted. If the password for root is lost, the product must be reset to the factory default settings. See Reset to Factory Default Settings on page 53.

To set the password via a standard HTTP connection, enter it directly in the dialog.

To set the password via an encrypted HTTPS connection, follow these steps:

1.Click Use HTTPS.

A temporary certificate (valid for one year) is created, enabling encryption of all traffic to and from the product, and the password can now be set securely.

2.Enter a password and then re-enter it to confirm the spelling.

3.Click OK. The password has now been configured.

Camera Orientation

This setting is defined the first time the product is accessed. Depending on how the Axis product is installed, select ceiling, wall or desktop .

Your selection will affect the view mode settings in the product (for information on view modes see View modes on page 16).

To change these settings, the product must be restored to the original factory default settings. To reset or restore the product, go to Setup > System Options > Maintenance in the product’s web pages. For information about reset and restore, see Maintenance on page 51.

Set Power Line Frequency

Power line frequency is set the first time the Axis product is accessed and can only be changed from Plain Config (see page 53) or by resetting the product to factory default.

Select the power line frequency (50 Hz or 60 Hz) used at the location of the Axis product. Selecting the wrong frequency may cause image flicker if the product is used in fluorescent light environments.

Note

Power line frequency varies depending on geographic region. The Americas usually use 60 Hz, whereas most other parts of the world use 50 Hz. Local variations could apply. Always check with the local authorities.

The Live View Page

The controls and layout of the Live View page may have been customized to meet specific installation requirements and user preferences. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View page. The following provides an overview of each available control.

9

Image 9
Contents Axis M3007-P Legal Considerations About this DocumentLiability Intellectual Property RightsLearn More SupportAxis M3007-P Table of ContentsPerformance Considerations Network Connector Connectors and Buttons For technical specifications, see RJ45 Ethernet connector with Power over Ethernet PoESD Card Slot LED IndicatorsControl Button Status LED IndicationAccess from a Browser Access the ProductAccess from the Internet Set the Root PasswordCamera Orientation Set Power Line FrequencyLive View Click Use HttpsControls on the Live View Go to Setup EventsAxis Media Control viewer toolbar Manual TriggerPTZ Controls How to Stream H.264 Media StreamsAxis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis M3007-P Basic Setup Set Up the ProductVideo Set Up Video StreamsPixel Counter View modesOverview PanoramaDouble Panorama Quad View ImageClick Save to apply the new settings Direction264 Camera Settings Stream ProfilesImage Appearance White Balance Exposure SettingsWide Dynamic Range Shutter & GainView areas Date/Time Formats in the online help To enable overlaysOverlay Go to Video Video Stream and select the Image tabOverlay Image Use Overlay Text in an Action RuleGo to Video Overlay Image Go to Events Action Rules Privacy MaskDefault Viewer for Browsers Configure the Live ViewViewer Settings Browser Viewer DescriptionUser Defined Links Preset Positions PTZ Pan Tilt ZoomGuard Tour Controls AdvancedTo add a guard tour Go to PTZ Guard Tour and click AddCamera Tampering DetectorsMotion Detection Go to Detectors Camera TamperingMotion Detection Parameters Set Up Motion Detection WindowsAxis M3007-P Go to Setup Applications Install ApplicationApplications Application LicensesAxis M3007-P Events Set Up Action RulesConvert Event Types to Action Rules Go to Events Action Rules and click AddTriggers Add Recipients ActionsRecipient Types Set Up Email Recipients Create SchedulesGo to Events Schedules and click Add Go to Events Recurrences and click Add Set Up RecurrencesRecording List RecordingsContinuous Recording Go to Recordings ListClick Save to save and start the recording Languages Security System OptionsUsers IP Address FilterIeee CertificatesGo to System Options Security Ieee Go to Setup System Options Security Certificates Basic TCP/IP SettingsDate & Time NetworkIPv6 Address Configuration IPv4 Address ConfigurationAssign IP Address Using ARP/Ping ARP/PingAxis Internet Dynamic DNS Service Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service requires IPv4 DNS ConfigurationHost Name Configuration NTP ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4FTP QoS Quality of ServiceUPnPTM StorageRTP/H.264 BonjourFormat SD Card Mount and Unmount SD CardNetwork Share MaintenanceTo add a network share Go to System Options Storage Click Network ShareSupport Overview SupportSystem Overview Logs & ReportsReset to Factory Default Settings Plain ConfigFile Upload Upgrade the Firmware TroubleshootingEmergency Recovery Procedure Check the FirmwareProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyVideo and image problems, general Problems with streaming H.264Video Camera Settings Key framesStorage disruption Storage and disk management problemsRe-mount the storage device Reformat the SD card and then click MountTechnical Specifications Maintenance Built-in Function/group Specifications System ApplicationInstallation aids Data Streaming PowerPerformance Considerations ConnectorsM6.3