Bosch Appliances installation instructions REG-D1 Range Chart

Page 13

The REG-D1 units have a recommended operation range with specified optimal capture distance for each model as shown below. Any number plate recognition installation should aim to control the traffic through a lane.

Model

Range, ‘R’

Optimal

 

 

Distance*

REG-D1-816

12 – 22 ft 3.7 – 6.7 m

16 ft 4.9 m

REG-D1-825

20 – 34 ft 6.1 – 10.4 m

25 ft 7.6 m

REG-D1-835

27 ft – 48 ft 8.2 – 14.6 m

35 ft 10.7 m

REG-D1-850

40 ft – 68 ft 12.2 – 20.7 m

50 ft 15.2 m

REG-D1-875

55 ft – 80 ft 16.8 – 24.4 m

75 ft 22.9 m

ranges for use with number plates of size 12in x 6in (305mm x 152mm) – common in North America.

Model

 

Range, ‘R’

 

Optimal

 

 

 

 

 

Distance*

REG-D1-812

10

– 20 ft 3 –

6 m

16 ft 5 m

REG-D1-816

16

– 26 ft 5

8 m

23 ft 7 m

REG-D1-825

23 – 40 ft 7 – 12 m

33 ft 10 m

REG-D1-835

34 – 60 ft 11

18 m

50 ft 15 m

REG-D1-850

56 – 82 ft 17

25 m

72 ft 22 m

REG-D1-875

72 –

100 ft 22 – 30 m

92 ft 28 m

ranges for use with number plates of size 20.6in x 4.4in (524mm x 112mm) – common in the UK.

Figure 3 REG-D1 Range Chart

- 7 -

Image 13
Contents Installation Instructions Important Safety Instructions Page 89/336/EEC Electromagnetic Compatibility Directive Page Index REG D1 Camera Description Unpacking Guidelines Initial PreparationsGeneral Mechanical Specifications Mechanical SPECIFICATIONS-REG D1Power and Video Connections Input Power / Video Output ConnectionsMounting Specification REG-D1 Range Chart Maximum Vertical Angle Maximum Horizontal Angle Color Overview Camera Lens Setting Rear Housing Removal Remove Cap screw Loosen lens Vari-Focal and Auto-Iris Control Adjustments Problem Possible Likely Solution Cause Troubleshooting GuidePage Poor Color Picture Quality Safety and Precaution General Specifications Page Page Page Asia-Pacific