290A Installation Instructions

Maintenance

Annual maintenance is required to inspect all visible seals for wear and damage. Worn or damaged seals should be replaced.

Recommendation: Treat all visible seals with silicone at least once a year to prevent them from drying out and to aid opening and closing of the housing. Use an all-purpose silicone spray for use on electrical equipment and components, and also compatible with rubber, metal and plastic materials.

Clean the housing with a damp cloth only (not on the window). Do not use chemicals to clean the housing as this may affect the powder coat finish. The window should only be cleaned with a dry cloth.

Burnt fuses in the fused terminal block can be replaced to reinstate the power supply of the camera. Use a 5A, 250 VAC fuse and ensure that the mains is disconnected before beginning.

Specifications

Weatherproof to IP66

CE

Power requirement: 100-240V AC 60/50Hz

Operating temperature: -20°C to +42°C (-4F to 108F).

Approximate weight: 3.2 kg (7.1 lbs)

Color: RAL 9002 grey white

Specifications may change without prior notice.

Warning: The housing should not be installed in areas that are subject to many hours of direct sunlight as this may overheat and damage the camera beyond repair. The maximum temperature inside the housing should never exceed 50°C (122F).

INSTAL GUIDE HOUSING ENV WHITE r3.1

January 2007

Copyright © Axis Communications AB, 2007

Part No. 28432

 

 

Image 8
Contents Fitting the camera inside the housing UnpackingRouting the cables Installing the housing Power Network Cablecable Connecting the camera Axis 211A Completing the installation Maintenance Specifications