AXIS A1001 Installation Guide

Reader I/O connectors DC output: 12 V DC, max 300 mA 2x 4 configurable inputs/outputs: Digital input: 0 to max 40 V DC Digital output: 0 to max 40 V DC, open drain, 100 mA

READER I/0 1 &2

Power connector

DC input: 10–30 V DC, max 26 W

Max load on outputs: 14 W

DC IN

Page 15

AWG 28–16 (CSA)

AWG 30–14 (CUL/UL)

Power & Relay connector

DC output: 12 V DC, max 500 mA

Relay: 30 V DC, max 700 mA

RELAY & PWR

Power lock connector

 

 

2x 12 V DC

V

DC,

0 V DC, floating, or 12

max total load: 500 mA

 

LOCK

Auxiliary connector

DC output: 3.3 V DC, max 100 mA

Digital input: 0 to max 40 V DC;

Digital output: 0 to max 40 V DC, open drain, 100 mA

AUX

Reader data connectors

Max cable length: 30 m (98.4 ft) RS485 full duplex

RS485 half duplex Wiegand

READER DATA 1 & 2

Door connectors

Digital input: 0 to max 40 V DC

DOOR IN 1 &2

Network Connector

RJ45, PoE IEEE 802.3af/

802.3at Type 1 Class 3

Max load on outputs: 7.5 W

Image 15
Contents Installation Guide USA Contact Information Transportation Axis A1001 Installation Guide Axis A1001 Installation Guide Axis A1001 Installation Guide STP 192.168.0 Axis IP Utility Axis A1001 Installation Guide Axis A1001 Installation Guide Axis A1001 Installation Guide STP Axis A1001 Installation Guide Power connector STP Axis A1001 Installation Guide T10 Page Ver.1.1