AVerMedia Technologies MP3000, MP2016 Enable, PTZ Camera Setup, Camera Display, Name, Comment

Page 26

AVerMedia User’s Manual

 

EYES Pro/MP2016/MP3000/MP5000

3. Enable

Figure 1.

Check Enable to enable this camera for

Gray-scale image

 

monitoring. If a camera is not enabled, the

 

image from this camera will show as Figure

 

1 (gray scale) on the screen. This camera’s

 

sign in the menu will change to .

If a camera input is not physically connected to a camera, you need to de-select Enable, or the system will not reach its best performance.

AVerMedia User’s Manual

EYES Pro/MP2016/MP3000/MP5000

Settings for the image properties are configured for the designated card, which may also connect to other cameras. That means, the settings you make for this camera will apply to other cameras that connect to the same card.

The adjustment of image properties will result in inefficiency as the video format is set to be PAL for the unsupported hardware temporarily

5. PTZ Camera

PTZ Camera Setup

A. Select a Com Port where PTZ camera connector connected and

the PTZ Model you use (refer to your PTZ camera spec.) by the

4.Camera

Display:

Check Display to display the image from this camera on the screen. If you check Enable without checking Display, the image from this camera will show as Figure 2 (color) on the screen. Although the image is not shown on the screen, this camera is still performing Record When Motion Detected, Record When Start Monitoring, or Don’t Record, depending on which one you chose in the Monitoring section of the System Configuration.

Name:

Figure 2.

Color image

pull-down lists. And click Set to place your setting.

B. To control PTZ camera with server’s camera by entering PTZ Camera ID at the range of 2~225.

Preset Position Setup

A. Choose a position number by the pull-down list to set the monitoring position with the right side direction interface. Meanwhile the display you adjust will be shown on the upside.

B. Determine a Position Name for the position.

C. During AutoPan, Dwell determines the time for the camera to stay (1~60 seconds) at one position before rotating to the next position.

D. You can set the Speed (5~255 deg/s) with which the camera rotates from its current position to the next preset position.

E. Click Set to involve into the setting.

6. Update

In the Name field, you can set the name for the camera.

Comment:

This field allows you to add any remarks you have for this camera. Any comment left can serve as a reminder for system manager.

Image Properties:

You may set the following properties for the image of this camera. brightness contrast color saturation

 

Click this button to update the setting.

7.

Restore

 

Click this button to abort all the changes you made so far and

 

restore your last settings.

8.

Default

 

Click this button to change all values to their default settings.

43

44

Image 26
Contents AVerMedia Eyes Pro MP2016/MP3000/MP5000 Digital Video Surveillance SystemAVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 ENGIntroduction 126 102106 147Introduction Hardware Recommendations Installing the Video Cards Eyes Pro Connecting the AVerMedia Video CardsAttaching Cameras Connecting External Sensor/Relay Coil Ratings at 20 oCExternal I/O Box Pin Signals Pin # Definition Relay OutputsCheck Your Windows Version Driver InstallationInstalling the Driver in Windows 98SE/Me Select Specify a location and click the Next button Installing the Driver in Windows Click the Yes button to proceed with the installation AVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 Installing the Driver in Windows XP After the installation finished, click the Finish buttonRemove Your Video Card Driver Software Installation AVerMedia Eyes Pro/MP2016/MP3000/MP5000 surveillance systemAVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 Product Update Product Present H/WSpecial Consideration System Configuration and OperationSystem Configuration Defrag Your Hard DiskAlarm & Relay Status Network Status Ask for password when login Miscellaneous Beep if no signal Auto Reboot Assign Recording DisksDisplay & Recording Rate UPS Uninterruptible Power SupplyVideo Product Camera SetsDefault UpdateRestore Camera IDSelect a Com Port where PTZ camera connector connected EnablePTZ Camera Setup Preset Position SetupAVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 Audio PropertiesMotion Detection Sensitivity Record when start monitoringRecord when motion detected Record with Time StampEdit ContentShield Start/ Stop MonitoringAVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 Test RelaysSound Alarm You may right-click the mouse on Alarm to add a new alarmAlarm ID ConditionsAVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 General Server IP Event LogDomain Name & Password Enable WebCam ServerAsk for password when remote clients login PortBy Date By WeekdayAVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 Task Enable Network ServerAlarm MonitorServer Delete all. Don’t make copies MoveCopy DeviceLocation Schedule BackupStatistic Start TimeDays before scheduled dates CameraInformation Configure e-map ImportArrange Cameras, Sensors, and Relays Add New UsersAuthorization Level AVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 DeleteSystem Operation Product Models Eyes Pro/MP3004/MP5004Eyes Pro/MP2016/MP3016/MP5016 Display ModesStart / Stop AutoScan 10/13-Camera DisplayFull Screen Display AVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 Map Start / Stop MonitoringStart / Stop Audio Recording Check out Cameras, Sensors, Relays on the mapRed System ConfigurationCamera Blue Camera GreenSelect Time Audio PlaybackSelect Files to Play AVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 PlayVideo Search AVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 ZoomPrint & Save Event SearchIntelligent Search Exit AVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 Focus Preset Position NoPTZ Control Direction & Speed AutoPan Path GroupExit PTZ Controller Date / Time Exit / Re-login Eyes Pro/MP2016/MP3000/MP5000Hard Disk Status Using the WebCam Enable WebCamCheck Enable WebCam server Use the WebCamRemoteManager Accessing RemoteManagerLogin Display Mode Alarm ReportSetup Channel StatusMinimum Space Minimum Space & Safety QuotaSafety Quota 112 Relay Status Network SetupSensor Status Back to Main Menu Click Alarm Control to see the window for alarm statusOperating the RemoteManager Center ManagementConneting quality Camera Setup, please refer to 6.2.3 Camera Setup sectionUser AVerMedia User’s Manual Eyes Pro/MP2016/MP3000/MP5000 PlaybackPrint Reverse PlaybackZoom In/Out SaveChannel PTZ ControlFocus out Direction ControlDirection Speed Zoom outExit RemoteManager Appendix a Remote Login with an Modem-to-Modem ConnectionStart Recording Windows 98SE / Windows Me128 130 Windows 134 136 Windows XP Click the Finish button to complete the connection setupGo to StartÆProgramsÆAccessoriesÆCommunications Click New Connection Wizard. Click the Next button140 142 Enter the name of this connection and click the Next button 146 Appendix B Registering Domain Name on Ddns Server User LoginPassword Appendix C Image Verification Steps to install and run ImageVerify programSetup/start program Verify image file. Click verify button to begin the processLimited Warranty 153
Related manuals
Manual 79 pages 404 b