Grandstream Networks GXW410X Line #, AC Impedance, CPT Detection, External Number, Automatically

Page 22

TABLE 9: FXO LINE TEST TAB DEFINITIONS

 

 

 

 

 

 

 

 

 

Note: The user can only test the parameters for only one of the PSTN lines at the

 

 

 

 

same time. In all cases please enter the telephone numbers as if the lines were to

 

 

 

 

dial each other locally.

 

 

 

 

 

For the AC Impedance Test we only need to select the line to be tested by clicking

 

 

 

 

on the AC impedance box corresponding to that line, telephone numbers are

 

 

 

 

optional. Remember that the AC impedance test is usually used to reduce the echo

 

 

 

 

that might be present in the line.

 

 

 

 

 

For the CPT test (call progress tones) we will test current disconnect as well. You

 

 

 

 

will need 2 telephone numbers to perform the test. You can only perform the test on

 

 

 

 

one line (row) at the same time and it will be the one that has the box checked for

 

 

 

 

testing. This tested line will use another line connected to the gateway to perform

 

 

 

 

the test by calling into it, this is why you will have to enter the telephone number for

 

 

 

 

a second line to help with the test.

 

 

 

 

 

For CID detection you will need 2 telephone numbers to perform the test. You can

 

 

 

 

only perform the test on one line (row) at the same time and it will be the one that

 

 

 

 

has the box checked for testing. This tested line will use another line connected to

 

 

 

 

the gateway to perform the test by calling into it, this is why you will have to enter

 

 

 

 

the telephone number for a second line to help with the test.

 

 

 

 

 

To perform the test, please select the line you want to test and the desired test to be

 

 

 

 

performed. Enter the information for this line as well as a second line if necessary.

 

 

 

 

Then click on the update button and then reboot. Log back in and now you should

 

 

 

 

see the information for the line selected as well as the check box already marked

 

 

 

 

already there. Go ahead and start the test now, please wait a few minutes until the

 

 

 

 

test is done.

 

 

 

 

 

Notes:

 

 

 

 

 

It is not required to enter a telephone number when testing for impedance, as the

 

 

 

 

system does not place any actual calls for the test.

 

 

 

 

 

If you log into the Web Interface while the test is running will not interrupt the

 

 

 

 

process.

 

 

 

 

 

 

 

 

 

 

 

 

 

Line #

 

Enter the telephone (PSTN) number that corresponds to this line. Enter it as if you

 

 

 

 

were going to dial it locally.

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Impedance

 

Select this box if you want to test for impedance on the line that is on the same row

 

 

 

 

as the checked box. Remember that you can only check one item at the same time.

 

 

 

 

 

 

 

 

 

 

 

 

CPT Detection

 

Select this box if you want to test for call progress tones and current disconnect

 

 

 

 

threshold on the line that is on the same row as the checked box. Remember that

 

 

 

 

you can only check one item at the same time.

 

 

 

 

 

 

 

 

 

 

 

 

 

External Number

 

Enter an external telephone (PSTN) number to be used as an auxiliary number for

 

 

 

 

the test. This is used only if we do not have at least 2 PSTN lines connected to the

 

 

 

 

gateway. This is only used for CPT and current disconnect threshold testing. In

 

 

 

 

order to use this function you will have to monitor the Syslog output. This is only

 

 

 

 

reserved for very advanced users.

 

 

 

 

 

 

 

 

 

 

 

 

 

External Call Timeout

 

This is the time the GXW will wait for the external telephone number to pick up

 

 

 

 

during the test.

 

 

 

 

 

 

 

 

 

 

 

 

 

Apply test results

 

Default is No. If selected on Yes, then all the results from the test will be applied

 

 

automatically

 

automatically. If you select No you will have to monitor the Syslog output. This is

 

 

 

 

only reserved for very advanced users.

 

 

 

 

 

 

 

 

 

 

 

 

 

Apply test results to all

 

Default is No. If selected on Yes, then all the test results will be applied to all ports

 

 

ports

 

on the gateway. If all the lines belong to the same service provider or PBX it will

 

 

 

 

make sense to apply the results to all ports.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grandstream Networks, Inc.

 

GXW410x User Manual

Page 22 of 35

 

Firmware Version 1.3.4.13

 

 

Last Updated: 3/2012

Image 22
Contents Grandstream Networks, Inc Table of Contents Table of Figures Welcome Packaging Connecting the GXW410XLAN or PC LEDs 1 Ready LEDVideo LED Busy onFXO Lines Or 8 Ports Anywhere in the worldGrandstream IP Pstn Analog endpoints GXW-410xFXS Gateway with GXW410x No SIP Server required Channels Software Features Overview Hardware SpecificationOn/Off Switch IP settingsLED Indicators Pstn SignalingConfiguration Guide Configuration with WEB BrowserPPPoE password Web AccessEnd-User Password PPPoE Service NameDaylight Savings Time Product Model Hardware RevisionMAC Address Software VersionAdvanced User Settings Prefix Config File Path Config ServerPostfix Config File AuthenticateNTP server Option 42 to Override an NTP Server Enable VideoSyslog Level SurveillanceConfiguring the FXO Channels Impedance Min. Delay beforeAC Termination Wait for Dial-toneCaller ID Transport SettingCaller ID Scheme TypeAC Impedance External Call TimeoutLine # CPT DetectionAuthentication Password Error TimeoutAuthentication ID Channel Voice SettingsLocal SIP Listen Port No Key Entry TimeoutSrtp Mode Round Robin and/orX10ms Use Dtmf Parameter Hookflash DurationFrom RFC2833 or SIP Info Profiles Enable 100rel TimerForce Timer Answer TimeoutSaving the Configuration Changes  Gateway side Video Surveillance ProceduresVideo Surveillance ∙ Deviceipaddress is the device IPPC client side running VLC as monitoring station Firmware Upgrade Through TFTP/HTTP/HTTPS Software UpgradeInstructions for local firmware upgrade Firmware and Configuration File Prefix and Postfix Configuration File DownloadManaging Firmware and Configuration File Download Restore Factory Default Setting Factory ResetGXW-410x Grandstream IP Pstn Analog Examples of GXW410X ConfigurationsFXO Lines CloudPstn Cloud
Related manuals
Manual 36 pages 967 b Manual 9 pages 33.93 Kb

GXW410X specifications

Grandstream Networks, a leading provider of IP voice and video communication solutions, has made a significant mark in the telecommunications industry with its GXW410X series of Analog Gateway devices. These gateways serve as a bridge between traditional analog phone systems and modern IP networks, making them an ideal solution for businesses looking to enhance communication efficiency while leveraging existing infrastructure.

At the heart of the GXW410X series is a range of models designed to support different analog port configurations, including the GXW4104, GXW4108, and GXW4116, which provide 4, 8, and 16 FXS ports, respectively. This flexibility allows organizations to choose the right model that fits their specific needs, whether they are a small business or a larger enterprise.

One of the standout features of the GXW410X is its robust SIP (Session Initiation Protocol) support, which facilitates easy connectivity to various VoIP service providers. This capability ensures that users can make and receive VoIP calls over their existing analog lines, reducing operational costs while improving call quality. The device also supports up to 1000 SIP accounts, allowing multiple users to make simultaneous calls without compromising performance.

The GXW410X series provides advanced call management features, including caller ID, call waiting, call forwarding, and voicemail, which empowers users to enhance their communication experience. Additionally, it offers integrated NAT (Network Address Translation) support and security features such as built-in firewall and encryption protocols, ensuring secure operations within the IP network.

The scalability of the GXW410X series is another remarkable characteristic. It enables seamless expansion for businesses as they grow, with the ability to easily connect additional analog devices to the network without significant infrastructure changes. Furthermore, the installation and configuration processes are user-friendly, thanks to the intuitive web-based management interface that simplifies monitoring and administration tasks.

Power over Ethernet (PoE) support is also included in the GXW410X series, allowing devices to receive power via the same Ethernet cable used for data transmission. This feature reduces the need for additional power adapters and simplifies deployment in various environments.

In summary, Grandstream Networks' GXW410X series of Analog Gateways combines sophisticated technology with practical features to deliver a reliable and cost-effective communication solution. With its SIP support, extensive call management options, security measures, and scalability, the GXW410X is an excellent choice for organizations looking to modernize their telephony systems while optimizing their resources. This device epitomizes Grandstream's commitment to quality, reliability, and innovation in the telecommunications space.