Paradyne FrameSaver DSL, 9783 manual System and Test Status Messages, Self-Test Results Messages

Page 111

Operation and Maintenance

System and Test Status Messages

System and test status information is selected from the Status menu.

Main Menu Status System and Test Status

The following information is included on this screen:

HSelf-Test Results Messages

HLast System Reset Date and Time

HHealth and Status Messages

HTest Status Messages

Self-Test Results Messages

One of these self-test result messages appear in the Self-Test Results field at the top of the System and Test Status screen.

Table 6-6. Self-Test Results Messages

Message

What It Indicates

What To Do

Failure xxxxxxxx

An internal failure occurred (xxxxxxxx represents an

8-digit hexadecimal failure code used by service personnel).

Record the failure code before resetting the unit; otherwise, the error information will be lost.

1.Record the failure code.

2.Reset the unit.

3.Contact your service representative.

Passed

No problems were found during power-on or reset.

No action needed.

Last System Reset Date and Time

This field indicates the last time the FrameSaver unit was reset. It appears after the Self-Test Results field at the top of the System and Test Status screen.

HDate is in mm/dd/yyyy format (month/day/year).

HTime is in mm:ss format (minutes:seconds).

9783-A2-GB20-00

July 2000

6-13

Image 111
Contents FrameSaver DSL Copyright E 2000 Paradyne Corporation All rights reserved Contents Configuration Options Operation and Maintenance Troubleshooting Setting Up Network Health for FrameSaver Devices Index About This Guide Purpose and Intended AudienceDocument Organization Setting Up OpenLane for FrameSaver Devices. Identifies Troubleshooting. Provides device problem resolutionAlarm, and other information, as well as troubleshooting Test proceduresProduct-Related Documents Highlighted text When viewing this manual online. Click onConventions Used To indicate a hyperlink to additional informationAbout the FrameSaver DSL Unit System OverviewSystem Overview Features FrameSaver DSL Features and Benefits9783-A2-GB20-00 July Benefits Frame Relay DSL ATMFrameSaver DSL Feature Sets Basic Advanced Feature Feature SetBasic Features Maximum Number of PVCs and Management PVCs Supported Advanced SLV Features OpenLane SLM System About the FrameSaver DSL Unit User Interface Basic Operation Logging On ProcedureIf your login was Then Select Main MenuScreen Work Areas Screen Format DescriptionThis is a remote-site unit that supports 8 PVCs and has Navigating the Screens Keyboard KeysPress Select For the screen Press Enter to Function Function KeysSelecting from a Menu Switching Between Screen AreasSelecting a Field Entering InformationExample User Interface and Basic Operation Configuration Procedures Configuration Menu Basic ConfigurationConfiguration Option Area Description Configuration Option AreasMain Menu → Configuration Accessing and Displaying Configuration OptionsConfiguration → PVC Connections Changing Configuration OptionsSaving Configuration Options Overview Configuration OptionsConfiguration Options Using the Easy Install Feature Main Menu → Easy InstallEasy Install Screen Example Easy Install Configuration Options 1 TS Access DlciTS Access VPI Ethernet Port Options Screen Easy Install Configuration Options 2TS Access VCI Create a Dedicated Network Management LinkMain Menu → Control → System Information Setting Up So the Router Can Receive RIPEntering System Information Setting the System Clock Configuration → Data Ports → Dlci RecordsConfiguring the Overall System Configuration Option TablesLMI Behavior Configuring Frame Relay and LMI for the SystemMain Menu → Configuration → System → Frame Relay and LMI System Frame Relay and LMI Options 1LMI Status Enquiry N1 Possible Settings 1, 2, 3, 4 LMI Heartbeat T1 Possible Settings 5, 10, 15, 20, 25System Frame Relay and LMI Options 2 Service Level Verification Options 1 Configuring Service Level Verification OptionsService Level Verification Options 2 SLV Timeout Clearing Event ThresholdSLV Packet Size bytes General System Options Configuring General System OptionsMain Menu → Configuration → System→ General Test TimeoutNetwork Physical Interface Options Configuring the Physical InterfacesConfiguring the Network Interface Main Menu → Configuration → Network → PhysicalTransmit Clock Source Configuring the User Data PortMain Menu → Configuration → Data Ports → Physical Data Port Physical Interface Options 1Data Port Physical Interface Options 2 Monitor DTRPort DTE Initiated Loopbacks LMI Parameters Configuring Frame Relay for the Data PortMain Menu → Configuration → Data Ports → Frame Relay Data Port Frame Relay Options 1Data Port Frame Relay Options 2 Network ATM Options Configuring ATM for the Network InterfaceMain Menu → Configuration → Network → ATM Cell Delineation Error Event ThresholdVPI,VCI Number VPI Configuring Circuit and Dlci RecordsDlci Record Options 1 Dlci NumberCommitted Burst Size Bc Bits Dlci Type Possible Settings Standard, MultiplexedDlci Record Options 2 CIR bpsOutbound Management Priority Dlci Record Options 3Excess Burst Size Bits Dlci PriorityConfiguring PVC Connections Main Menu → Configuration → PVC Connections10. PVC Connection Options 1 Destination Edlci 10. PVC Connection Options 2Destination Link Destination DlciConfiguring Node IP Information Setting Up Management and Communication Options11. Node IP Options 1 11. Node IP Options 2 11. Node IP Options 3 TS Access Management LinkConfiguring Management PVCs 12. Management PVC Options 1Name Primary Link Possible Settings Net1-FR1, Port-1, Clear 12. Management PVC Options 2Set DE 12. Management PVC Options 3 Primary DlciPrimary Edlci Snmp Management Configuring General Snmp ManagementName 1 Access 13. General Snmp Management Options 113. General Snmp Management Options 2 Name 2 AccessTelnet Session Configuring Telnet and/or FTP Session SupportTelnet Login Required 14. Telnet and FTP Session Options 1Inactivity Timeout 14. Telnet and FTP Session Options 2Disconnect Time Minutes FTP Max Transfer Rate Kbps FTP Login Required14. Telnet and FTP Session Options 3 FTP SessionNMS IP Validation Configuring Snmp NMS SecurityAccess Type 15. Snmp NMS Security OptionsNumber of Trap Managers Configuring Snmp Traps16. Snmp Traps Options 1 Snmp TrapsEnterprise Specific Traps 16. Snmp Traps Options 2Rmon Traps Link Traps Possible Settings Disable, Up, Down, Both16. Snmp Traps Options 3 Link Traps InterfacesConfiguring the Ethernet Port 17. Ethernet Port Options 1Interface Status Proxy ARP 17. Ethernet Port Options 2Character Length Configuring the Communication Port18. Communication Port Options 1 Port UseIgnore Control Leads Login Required18. Communication Port Options 2 Stop Bits18. Communication Port Options 3 RIP 18. Communication Port Options 419. External Modem COM Port Options Configuring the COM Port to Support an External ModemExternal Modem Commands Dial-In AccessSecurity and Logins Controlling Asynchronous Terminal Access Limiting AccessSet the configuration option Controlling Telnet or FTP Access Controlling External COM Port Device AccessLimiting Telnet Access Limiting FTP Access Limiting Telnet or FTP Access Over the TS Management Link Disabling Snmp Access Controlling Snmp AccessAssigning Snmp Community Names and Access Levels Limiting Snmp Access Through IP Addresses Creating a Login Main Menu → Control → Administer LoginsField Enter Deleting a Login Modifying a LoginOperation and Maintenance Displaying System Information Main Menu → Status → IdentityView this field To find Viewing LEDs and Control Leads Main Menu → Status → Display LEDs and Control LeadsDisplay LEDs & Control Leads Screen General Status LEDs 1 Label Indication Color What It Means LED DescriptionsUser Data Port LED Label Indication Color What It Means Network Interface LEDs Label Indication Color What It MeansUser Data Port Control Lead DescriptionsAdditional Control Leads Label Indication What It Means Network InterfaceDevice Messages 1 What It Indicates What To Do Device MessagesSee Changing Software Device Messages 2 What It Indicates What To DoDevice Messages 3 What It Indicates What To Do See Upgrading System Device Messages 4 What It Indicates What To DoDevice Messages 5 What It Indicates What To Do Reset COM PortStatus Menu Status InformationSelf-Test Results Messages Last System Reset Date and TimeSelf-Test Results Messages Last System Reset Date and Time System and Test Status MessagesHealth and Status Messages 1 What It Indicates Health and Status MessagesFrame relay link Health and Status Messages 2 What It IndicatesFrame relay link 1, 2 Health and Status Messages 3 What It IndicatesTest Status Messages 1 What It Indicates Test Status MessagesSend Pttn Active, Interface Test Status Messages 2 What It IndicatesPVC Connection Status 1 Field PVC Connection StatusMain Menu → Status → PVC Connection Status PVC Connection Status Screen ExamplePVC Connection Status 2 Field What It Indicates 10. Network Interface Status Field What It Indicates Network Interface StatusMain Menu → Status → Network Interface Status Network Interface Status Screen ExampleIP Routing Table Main Menu → Status → IP Routing TableIP Routing Table Screen Example 11. IP Routing Table Values Column What It Indicates Performance Statistics Main Menu → Status → Performance StatisticsPerformance Statistics Menu Performance Statistics → ESF Line Clearing Performance StatisticsPerformance Statistics → Clear All Statistics Performance Statistics → Frame RelayService Level Verification Performance Statistics Average round trip latency is measured every SLV sampling Dlci Performance Statistics Main Menu → Status → Performance Statistics → Dlci13. Dlci Performance Statistics 1 What It Indicates CIR&EIR 13. Dlci Performance Statistics 2 What It Indicates14. Frame Relay Performance Statistics 1 What It Indicates Frame Relay ErrorsFrame Relay Performance Statistics Main Menu → Status → Performance Statistics → Frame RelayFrame Relay LMI Frame Relay Errors contdFrame Relay Hdlc Errors 14. Frame Relay Performance Statistics 2 What It IndicatesTC Sublayer ATM Performance StatisticsMain Menu → Status → Performance Statistics → ATM 15. ATM Performance Statistics 1 What It Indicates15. ATM Performance Statistics 2 What It Indicates Ethernet Performance Statistics Main Menu → Status → Performance Statistics → EthernetStatistic What It Indicates Trap Event Log Main Menu → Status → Trap Event LogTrap Event Log Screen Example Operation and Maintenance FTP Operation FTP File Transfers Dir directory Command DefinitionIf the message displayed is Then Upgrading System SoftwareChanging Software Determining Whether a Download Is CompletedIf retrieving Then Transferring Collected DataTroubleshooting Indicators See Problem IndicatorsResetting the Unit and Restoring Communication Resetting the Unit from the Control MenuResetting the Unit By Cycling the Power If selecting Following occurs Restoring Communication with an Improperly Configured UnitTroubleshooting Management Link Feature LMI Packet Capture Utility FeatureMain Menu → Control → LMI Packet Capture Utility LMI Trace Log Example LMI Packet Capture Utility → Display LMI Trace LogAlarm Conditions 1 What It Indicates What To Do AlarmsAlarm Conditions 2 What It Indicates What To Do Alarm Conditions 3 What It Indicates What To Do Alarm Conditions 4 What It Indicates What To Do Device Problems 1 Symptom Possible Cause Solutions Troubleshooting TablesDevice Problems See Trap Event Log in , Operation and MaintenanceUnit Device Problems 2 Symptom Possible Cause SolutionsATM Problems Symptom Possible Cause Solutions ATM ProblemsFrame Relay PVC Problems Symptom Possible Cause Solutions Frame Relay PVC ProblemsTest Menu Example Tests AvailableTest Timeout Feature When the status of a test is Only command available isStarting and Stopping a Test Active Aborting All TestsPVC Tests Screen Example PVC TestsMain Menu → Test → Data Port PVC Tests PVC LoopbackSend Pattern Main Menu → Test → Network PVC TestsConnectivity Monitor PatternMain Menu → Test → Data Port Physical Tests DTE LoopbackMain Menu → Test → IP Ping IP Ping TestProcedure Main Menu → Test → Lamp Test Lamp TestSetting Up OpenLane for FrameSaver Devices OpenLane Support of FrameSaver DevicesOpenLane Support of FrameSaver Devices Setting Up the OpenLane SLM System Setting Up FrameSaver and SLV Support Setting Up OpenLane for FrameSaver Devices 10-1 Setting Up Network Health for FrameSaver DevicesInstallation and Setup of Network Health Discovering FrameSaver Elements Configuring the Discovered Elements Grouping Elements for Reports About Service Level Reports Generating Reports for a GroupAbout At-a-Glance Reports Reports Applicable to FrameSaver SLV Devices About Trend ReportsPrinted Reports 10-8 10-9 10-10 Menus Menu HierarchyStatus Menu Hierarchy Frame Relay ModeControl Easy InstallMenu Hierarchy Snmp MIBs and Traps, Rmon Alarm Defaults Downloading MIBs and Snmp Traps MIB SupportSystem Group mib-2 FrameSaver Units sysDescr systemFrameSaver Units sysObjectID system Frame Relay Logical Layer Interfaces Group mib-2Paradyne Indexes to the Interface Table ifTable Physical LayerRmon Logical Layer NetScout Indexes to the Interface Table ifTableExamples Standards Compliance for Snmp TrapsVariable-Binding Trap authenticationFailureTrap warmStart Table B-3. warmStart Trap What It Indicates Possible CauseTraps linkUp and linkDown Sample strings Physical SublayerInterface Variable-Bindings Possible Cause Table B-6. linkUp and linkDown Variable-Bindings 2ATM Logical Link Sublayer DevHealthAndStatus Traps enterprise-SpecificSLVs devFrExt.mib Placeholder Traps RMON-Specific Rising Event Operation Rmon Alarm and Event DefaultsEvent Defaults EventIndex EventDescription EventTypePhysical Interface Alarm Defaults Frame Relay Link Alarm Defaults Snmp MIBs and Traps, and Rmon Alarm Defaults MIB FR DTE MIB Dlci Alarm Defaults ± Paradyne AreaFrames Sent Snmp MIBs and Traps, and Rmon Alarm Defaults Object ID Cross-References Numeric Order 6.1.2.1.2.2.1 6.1.2.1.2.10.32.2.16.1.4.1.1795.2.24.2 Dlci CIR 6.1.4.1.1795.2.24.2.6.9.46.1.4.1.1795.2.24.2.6.9.4.4.2 Dlci EIR6.1.4.1.1795.2.24.2.6.9.4.7.1 6.1.4.1.1795.2.24.2.6.9.4.5.2.16.1.4.1.1795.2.24.2.6.9.4.10.3.1 6.1.2.1.10.32.2.1 Snmp MIBs and Traps, and Rmon Alarm Defaults Rear Panel Connectors, Cables, Pin AssignmentsDSL Network Interface Cable Figure C-1. DSL Network Interface Cable with RJ48C ConnectorSignal Direction Pin # COM Port ConnectorPin Standard EIA-232-D Crossover CableAT Command String To configure the modem to Data Port Connector Standard V.35 Straight-through CableDirection Pin Socket Ethernet Port Connector Connectors, Cables, and Pin Assignments Technical Specifications Data Port COM PortDSL Network Interface Ethernet PortEquipment Model / Feature NumberFrameSaver SLV Upgrade Equipment ListCables Description Model / Feature NumberDescription Part Number Feature Number Optional FeaturesNumbers IndexIN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9