MXD254B OPERATION
Troubleshooting
Problem
Cause
Action
Unit will not turn on
(no power)
Unit has power (but no sound)
Unit blows fuses
Excessive skipping
Unit will not accept
a disc
Yellow wire not connected or incorrect voltage | Check connections for proper voltage |
Red wire not connected or incorrect voltage | (11~16VDC) |
|
|
Black wire not connected | Check connection to ground |
|
|
Fuse blown | Replace fuse |
Speaker wires not connected | Check connections at speakers |
|
|
One or more speaker wires touching each | Insulate all bare speaker wires from |
other or touching chassis ground | each other and chassis ground |
|
|
Yellow or red wire touching chassis ground | Check for pinched wire |
Speaker wires touching chassis ground | Check for pinched wire |
|
|
Incorrect fuse rating | Use fuse with correct rating |
|
|
Unit is not mounted correctly or backstrap is | Check mounting sleeve and backstrap |
not secure | support |
|
|
Physical defect in media (CD, | Check media for scratches |
|
|
CD mechanism position out of alignment | Press EJECT for 3 seconds to reset |
| CD mechanism position |
|
|
CD transit screws still in place | Remove 2 transit screws located on top |
| of the unit. |
|
|
|
| Error Codes |
|
|
|
Error Code | Cause | Action |
Disc error | Press eject or RESET | |
|
|
|
Mechanism error | Press eject or RESET | |
|
|
|
Servo error or disc is in upside down | Press eject or RESET | |
|
|
|
9