MXD254B OPERATION
Troubleshooting
Problem
Cause
Action
Unit will not turn on
(no power)
Unit has power (but no sound)
Unit blows fuses
Excessive skipping
Unit will not accept
a disc
| Yellow wire not connected or incorrect voltage | Check connections for proper voltage | 
| Red wire not connected or incorrect voltage | (11~16VDC) | 
| 
 | 
 | 
| Black wire not connected | Check connection to ground | 
| 
 | 
 | 
| Fuse blown | Replace fuse | 
| Speaker wires not connected | Check connections at speakers | 
| 
 | 
 | 
| One or more speaker wires touching each | Insulate all bare speaker wires from | 
| other or touching chassis ground | each other and chassis ground | 
| 
 | 
 | 
| Yellow or red wire touching chassis ground | Check for pinched wire | 
| Speaker wires touching chassis ground | Check for pinched wire | 
| 
 | 
 | 
| Incorrect fuse rating | Use fuse with correct rating | 
| 
 | 
 | 
| Unit is not mounted correctly or backstrap is | Check mounting sleeve and backstrap | 
| not secure | support | 
| 
 | 
 | 
| Physical defect in media (CD,  | Check media for scratches | 
| 
 | 
 | 
| CD mechanism position out of alignment | Press EJECT for 3 seconds to reset | 
| 
 | CD mechanism position | 
| 
 | 
 | 
| CD transit screws still in place | Remove 2 transit screws located on top | 
| 
 | of the unit. | 
| 
 | 
 | 
| 
 | 
 | Error Codes | 
| 
 | 
 | 
 | 
| Error Code | Cause | Action | 
| Disc error | Press eject or RESET | |
| 
 | 
 | 
 | 
| Mechanism error | Press eject or RESET | |
| 
 | 
 | 
 | 
| Servo error or disc is in upside down | Press eject or RESET | |
| 
 | 
 | 
 | 
9