ELECTRICAL CONNECTIONS

Disconnect vehicle battery before making any electrical connections.

Electrical connections to the unit are made using a removable terminal block plug and screw terminals located on the amplifier. A label on the unit identifies each terminal function. Install the plug on the unit before wiring. If the unit needs service the plug can be easily removed without unwiring. The power supply of the unit must be capable of delivering peak currents up to 50 amps for adequate short circuit protection and reliable operation. The preferred source is directly at the vehicle battery. The amplifier is fused. Attach leads by stripping 3/8", inserting into plug and clamp by tightening screw. Make sure the screw is tight and the wire can’t be pulled out.

Failure to adequately tighten the screw can result in improper operation or burning the connector and wire.

Wire Size and Termination - The diagram shows the minimum wire size used for each connection, along with recommended lead color. If the wire is longer than 10 ft. use the next larger wire size. Use only high quality crimp connectors for installation on the vehicle.

Enable Input Connection (ORG lead on wiring diagram next page) - This is NOT the same as the main power connection. The enable input is like a power switch for the unit. When there is positive power at this connection, the unit is powered up and ready to function. When power is removed, the unit is not powered up and will not drain current from the battery. Connect to a positive circuit controlled by the vehicle ignition switch, usually a terminal at the vehicle fuse panel. The required current is low (15mA typ.).

For SC-1022:

The Enable Input must be connected.

For SC-1002 and SC-1012:

The Enable Input is optional.

If it is not desired to wire the Enable Input, set the Instant ON DIP switch as described under INSTALLER SELECTABLE OPTIONS. The unit will instantly turn on when a switch on the face of the unit or the control panel is activated. This includes LT1 and LT2 switches. When all switches are deactivated, the unit will turn off. Without the enable input, the Manual siren tone will stop immediately. LT1 or LT2 switch may be used as power switch for the unit instead of Enable Input.

Auxiliary Input Connection (Optional) - A momentary input typically connected to the horn ring of the vehicle or other switch. See OPERATION section for auxiliary input functions.

NOTE: Permanent disconnection of the vehicle horn is NOT recommended.

The auxiliary input may be activated with positive or negative voltage. See Auxiliary Polarity under INSTALLER SELECTABLE OPTIONS section for proper activation polarity. Input current is 1 to 20 mA.

Aux Input for SC-1002 and SC-1012:

The unit must be turned on for the Auxiliary Input to function. This is accomplished with either the siren controls or Enable Input.

Instant ON option set and unit turned on with

Unit turned on

Auxiliary Input

switch on face of unit or control panel. This includes LT1 or LT2.

with enable input

will Function

NO

NO

NO

YES

NO

YES

NO

YES

YES

YES

YES

YES

TB0362A

Page 5 of 14

05/28/10

Image 5
Contents Technical Bulletin Temperature Siren Mode Output PowerWeight Light Control Input PowerMounting Main unit InstallationSafety Precautions INSTALLER-SELECTABLE Options Will Function Electrical ConnectionsElectrical Connections ALL Models Enable Input must be connectedElectrical Connections SC-1012 only Front of UnitSC-1022 Electrical Connections SC-1022 onlyOperation LT1 and LT2 Pushbutton Switches MAN Pushbutton SwitchHorn Pushbutton Switch Problems ServiceSymptom Possible Cause Check ReturnDescription Accessory DescriptionSC-1002 Parts 10 12 9 11 SC-1012 PartsSC-1022 Parts
Related manuals
Manual 16 pages 61.52 Kb

1022-10 14 V, 1012, SC-1002 specifications

The Carson 1022-10 14 V, 1012, SC-1002 is a versatile piece of equipment that has gained recognition for its innovative design and robust performance in various applications. This advanced model is engineered to meet the demands of both industrial and commercial sectors, enhancing productivity while ensuring reliability.

One of the main features of the Carson 1022-10 is its powerful 14 V motor, which delivers efficient performance across a wide range of tasks. This high-voltage capability allows for quick and effective operation, making it an ideal choice for users who require consistent energy and speed. The design incorporates a durable casing that not only protects the internal components but also ensures longevity, making it suitable for heavy-duty use.

Another remarkable characteristic of the Carson 1022-10 is its user-friendly interface. The controls are intuitively placed, allowing users to operate the machine with ease. This feature is particularly beneficial in environments where time is of the essence, as it minimizes the learning curve for new users. The SC-1002 model also includes advanced safety features, such as overload protection and emergency shut-off mechanisms, ensuring a secure working environment.

The technology integrated into the Carson 1022-10 also sets it apart from its competitors. It employs a cutting-edge energy management system that optimizes power usage, thereby increasing efficiency while reducing operational costs. This system not only helps in conserving energy but also extends the lifespan of the equipment.

Additionally, the Carson 1022-10 supports several attachments and accessories, allowing it to adapt to various tasks effortlessly. This versatility makes it a valuable asset in settings ranging from manufacturing plants to construction sites. The compatibility with multiple tools enhances its functionality, making it suitable for diverse applications.

In summary, the Carson 1022-10 14 V, 1012, SC-1002 stands out for its powerful performance, user-centric design, and advanced technology. With its exceptional features and adaptability, this model continues to be a go-to solution for professionals seeking reliability and efficiency in their operations. Whether used in manufacturing or construction, it embodies a blend of power and precision that meets the evolving needs of today’s industries.