ELECTRICAL CONNECTIONS CONTINUED (ALL MODELS)

Auxiliary Input

Connection Examples

Momentary

HORN RLY +VDC or

Horn

 

Vehicle

Circuit

Horn

 

Activated with

+VDC OR -VDC

Factory Default

DIP SW-1 ON for +VDC

DIP SW-1 OFF for -VDC

SPST Switch

To

AUX

+VDC

or

-VDC

-VDC

Added

SPDT

Switch

Vehicle

To Horn

AUX

Splice

Note:

Vehicle horn will also

sound with siren

To

AUX

AUX

#22G WHT

 

Load 1 and Load 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable Input

 

Recommended Wire

 

Load

Gauge see table

 

 

 

 

 

 

 

 

(like an ON/OFF switch)

 

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

Connect to positive circuit

 

Amps

 

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#22G

(fuse panel) controlled by

 

5 - 10

 

#16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORG

ignition or other switch

 

10 - 15

 

#14

 

 

 

 

 

 

 

 

 

 

Gauge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 - 20

 

#12

 

 

Load

 

 

 

 

 

 

 

 

see table

 

 

 

On SC-1022

 

Use next larger size if

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

longer than 10 ft.

 

 

 

 

 

 

 

 

 

Enable Input must be connected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On SC-1002 / 1012

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable Input must be connected

 

 

 

#16G BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unless option SW-2 is set.

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See INSTALLER SELECTABLE

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#18G BRN

 

 

RED (Positive Supply)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended Wire Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Load 1 + Load 2 +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#18G BRN

 

 

8A for Amplifier

Gauge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 - 10

#16

 

10 - 15

#14

Plug installed

15 - 25

#12

25 - 28

#10

this orientation

 

Use next larger size if

6-P Terminal Block Plug

 

 

longer than 10 ft.

 

 

 

(CP4956-06)

 

 

25A Automotive

15A Automotive

 

Plug into unit first for

 

Type Fuse

Type Fuse

 

terminal identification

 

 

 

LITE

FUSE

Do not remove nut

POS

 

NEG

 

LT2

 

LT1

 

ENA

 

AUX

 

SPK

 

SPK

Back of Unit

SIREN

FUSE

Do not remove nut

TB0362A

Page 6 of 14

05/28/10

Image 6
Contents Technical Bulletin Weight Siren Mode Output PowerTemperature Light Control Input PowerInstallation Safety PrecautionsMounting Main unit INSTALLER-SELECTABLE Options Electrical Connections Will FunctionEnable Input must be connected Electrical Connections ALL ModelsFront of Unit Electrical Connections SC-1012 onlyElectrical Connections SC-1022 only SC-1022Operation MAN Pushbutton Switch Horn Pushbutton SwitchLT1 and LT2 Pushbutton Switches Symptom Possible Cause Check ServiceProblems ReturnAccessory Description SC-1002 PartsDescription SC-1012 Parts 10 12 9 11SC-1022 Parts
Related manuals
Manual 16 pages 61.52 Kb

1022-10 14 V, 1012, SC-1002 specifications

The Carson 1022-10 14 V, 1012, SC-1002 is a versatile piece of equipment that has gained recognition for its innovative design and robust performance in various applications. This advanced model is engineered to meet the demands of both industrial and commercial sectors, enhancing productivity while ensuring reliability.

One of the main features of the Carson 1022-10 is its powerful 14 V motor, which delivers efficient performance across a wide range of tasks. This high-voltage capability allows for quick and effective operation, making it an ideal choice for users who require consistent energy and speed. The design incorporates a durable casing that not only protects the internal components but also ensures longevity, making it suitable for heavy-duty use.

Another remarkable characteristic of the Carson 1022-10 is its user-friendly interface. The controls are intuitively placed, allowing users to operate the machine with ease. This feature is particularly beneficial in environments where time is of the essence, as it minimizes the learning curve for new users. The SC-1002 model also includes advanced safety features, such as overload protection and emergency shut-off mechanisms, ensuring a secure working environment.

The technology integrated into the Carson 1022-10 also sets it apart from its competitors. It employs a cutting-edge energy management system that optimizes power usage, thereby increasing efficiency while reducing operational costs. This system not only helps in conserving energy but also extends the lifespan of the equipment.

Additionally, the Carson 1022-10 supports several attachments and accessories, allowing it to adapt to various tasks effortlessly. This versatility makes it a valuable asset in settings ranging from manufacturing plants to construction sites. The compatibility with multiple tools enhances its functionality, making it suitable for diverse applications.

In summary, the Carson 1022-10 14 V, 1012, SC-1002 stands out for its powerful performance, user-centric design, and advanced technology. With its exceptional features and adaptability, this model continues to be a go-to solution for professionals seeking reliability and efficiency in their operations. Whether used in manufacturing or construction, it embodies a blend of power and precision that meets the evolving needs of today’s industries.