Audison LRX 5.600 manual CLK2 LRx Cooling Kit, Subsonic Filter CUT-OFF Frequency Modification

Page 11

ACCESSORIES

CLK2 - LRx Cooling Kit

This cooling system is specially designed to provide LRx amplifiers with the right working temperature.

CLK2 should be used when LRx amplifiers work in extremely hard conditions (very low loads) or in installations where space is too narrow and heat sink cooling is not enough. It consists of two units to apply onto the amplifier sides; each of them is provided with an electronically controlled fan. Its intervention depends on a thermal sensor that starts the system as soon as LRx heat sink reaches 45°C. The same sensor is connected to a special circuit which controls the two fans speed progressive increase when temperature increases, too.

Air flux constant control allows the amplifier very good thermal stabilization and limits noise.

SETTING PANEL

SUBSONIC FILTER CUT-OFF FREQUENCY MODIFICATION

Subsonic filter is pre-adjusted at 20 Hz. In order to modify this value, please act according to what follows.

Procedure:

 

S1

15K

100K

33K

39K

JFS1

SW1

C1

 

 

 

 

 

 

 

 

 

 

 

 

 

FS1

FS2

FS3

FS4

 

 

S2

 

 

 

 

 

 

C1

 

 

 

 

 

Replace FS1, FS2, FS3, FS4 resistors according to the values in the setting panel table.

 

 

mm

Remark: Cut the new resistors

 

5

 

rheophores according to the

 

 

 

 

 

 

 

 

10 mm

 

 

 

size in the picture.

 

 

 

 

 

 

 

VCA-VCA1D MODULES INSERTION

LRx 5.600 can accept one of the three optional kits which allow the subwoofer volume remote control: VCR01K, VCRAK or VCRDK.

These kits have a specific module, VCA or VCA1D, to insert into the amplifier through the setting panel.

Installation:

1 - Remove BYP12 bridge.

2 - Insert VCA/VCA1D module.

- Insertion key. It prevents the module from being inserted in the wrong way.

14

11

Image 11
Contents Audison measurement standards Introduction PrecautionsIntroduction Contents InstallationLRx 5.600 Fuse 50A DescriptionAmplifier Fixing Electric Connections Functions IN-OUT PanelLogo Rotation Channel FRONT+REAR Power Supply PanelConfiguration Examples MULTICHANNEL+SUB FRONT+REAR+SUB F-R ModeFuse Replacement Controls Panel Diagram and Configuration Switches Controls Panel ConfigurationsFunctions and Controls Configurations Table Subsonic Block DiagramControls Panel Ch. Select 5 Ch. 3 Ch. mono Setting PanelAccessories Amplifier ConfigurationVCA-VCA1D Modules Insertion InstallationCLK2 LRx Cooling Kit Subsonic Filter CUT-OFF Frequency ModificationLRx Technical FeaturesSize for Fixing VCR01K,VCRAK and Vcrdk