Knoll Systems MVP44a installation manual

Page 4

...System layout considerations continued

In certain commercial applications a microphone paging override is required. Model MR171 paging and override module takes a balanced or unbalanced mic, (with defeatable phantom power) or a line level input and when activated overrides all inputs (even if some or all zones are in standby) and pages at a preset volume in all zones.

A variety of door chime and telephone paging, door entry and front door camera modules are being developed. Check our web site for more information.

The MVP44a includes a 12VDC trigger output to control and power various items when the MVP44a is powered up. When the MVP44a agoes into standby the trigger output ends. It's maximum output is 60mA.

An innovative IR connection system is also included to turn on and off the various source components as well as four separate commands. A Xantech 590-00 controller is required for this purpose. The Xantech 590-00 is a an IR sequence generator. When it receives commands from the MVP44a it generates an IR command or sequence of up to 10 commands.

The on command is automatically generated when the MVP44a goes out of standby and into power up. The off command is automatically generated when the MVP44a goes from power on to standby. These sequences are generally used to turn on and off the source equipment.

To activate the four commands, when the system is powered up, press the MR60 keypad button FNC then quickly press one of the four source buttons on the top of the MR60 keypad. This will initiate a pulse at the MVP44a FUNCTION output, that in turn generates an IR command that is pumped back into the MVP44a IR emitter port 1 and out to the various emitters connected to ports 2-3-4, that will initiate the command to the source component.

4

in bank 1 positions 1 through 6).

The 590-00 can learn up to 16 different commands on each of its four banks. If more than 10 different IR commands are to be stored use bank 2, 3, and 4 to store the sequence commands and bank one positions 1-6 to execute the sequences.

1.Write down the order for each of the sequences required for all of the six functions (not programmed with single commands).

2.Turn the bank 2 dip switch on; bank 1, 3, and 4 off.

3.Push PGM (program lamp goes on).

4.Using the wire attached to the 590-00 +12VDC, touch and hold the other end of the wire to the 590-00 upper + row terminal 1. While holding the wire in place, press the remote control button of the first function while the remote is about 2-4" from the 590-00 internal infrared sensor. The 590-00 PROGRAM lamp will flicker while storing the IR signal. When the IR signal is stored, the confirm lamp comes on. Release the remote control button and release the wire to the upper row terminal. The IR signal is now stored in the 590-00 bank 2 terminal 1.

5.Hold the end of the wire to the 590-00 upper + row terminal

2.While holding the wire in place, press the remote control button of the second function while it is about 2-4 inches from the 590-00 internal infrared sensor. The 590-00 PROGRAM lamp will flicker while storing the information. When the information is stored, the confirm lamp will come on. Release the remote control button and release the wire to the upper row terminal. The IR signal is now stored in the 590-00 bank 2 terminal 2.

6.Continue this procedure until all of the required sequence commands have been learned by the 590-00. If more than 16 IR signals have to be learned, fill up bank 2 with the first 16 IR signals, then turn the bank 2 dip switch off, and the bank 3 switch on. Continue with bank 3 position 1, 2 etc. Use bank 4 positions 1, 2, etc., if required and bank 1 positions 7-16.

Note: When storing an IR signal command sequence, it is most reliable if commands to a component are timed as far apart as

13

Image 4
Contents Specifications MVP44a 8 Channel Power Amplifier Limited WarrantyVersion Key Features TroubleshootingSystem layout considerations Never connect the MVP44a to 2 ohm loadsPage Single IR Command Storing InstallationSequence IR Command Storing MVP44a Activation Power OnProgramming Wiring the 590-00 to the MVP44a See the diagram onMVP44a to Xantech MR60 keypad functions RJ45 plug color and pair wiring guideRJ45 plug function identification