Redring 650 manual Plumbing see diagram

Page 7

7. If you have not yet done so, remove the front cover

(complete with control knob) of the unit by undoing

 

the retaining screws at the top and bottom of the

 

unit and lifting the cover off. The top-fixing hole is a

 

keyhole slot, and should be marked and drilled

 

first. Tighten top screw with head protruding about

 

10mm from wall and hook the back-plate over the

 

screw head. This allows for correct and accurate

Diagram 7

alignment of your shower before marking and fixing

 

the bottom/side position. You may not wish to

 

tighten up all 3 screws at this stage as the holes

 

are elongated to allow for adjustment after other

 

connections have taken place.

 

WARNING! TAKE CARE NOT TO DAMAGE THE

Diagram 8

PRINTED CIRCUIT BOARD IN ANY WAY. DURING

 

INSTALLATION AVOID DUST AND DEBRIS

 

GETTING ON IT.

 

8.Do not obstruct the pressure relief device found in the back-plate slot underneath the outlet connection (see diagram 2). Especially if silicone sealant or similar materials are used around the edges of the back-plate.

9.There are a number of clearly marked shields in

the shower unit. These are important for the correct operation of this shower and MUST NOT be removed under any circumstances.

b) Plumbing (see diagram 9)

The heater should be connected to the mains cold water supply. This must have a minimum running pressure of 100kPa, 1.0 bar (14.5 p.s.i) and a maximum pressure of 1000kPa, 10 bar (145 p.s.i).

Before connecting the pipe-work to the shower ensure that pipe-work is flushed out.

1.It is recommended that a WRAS (Water Regulations Advisory Scheme) listed isolating valve is fitted between the rising main and the unit. This will allow the unit to be serviced without turning off the cold water or exchanged without having to turn off the water at the water mains stop valve.

2.The heater can be fed from a header tank provided this has a minimum head height of 10.5 metres (35ft).

3.15mm copper or stainless steel pipe should be used alongside with a standard compression fitting. In multiple shower installations correct pipe-work sizes should be calculated to maintain adequate flow to each shower.

4.a) If top entry is chosen, turn the elbow 180° into the required position and fit a standard 15mm in line compression fitting. There is a removable side section, which will aid you with this (diag.7).

b) If rear entry is chosen, turn the elbow 180° and treat it as top entry except for the fitting of a ‘Yorkshire’ elbow in the rear channel. The removable side section will again be an aid.

5.It is in order to use a WRAS (Water Regulations Advisory Scheme) approved sealant sparingly whilst avoiding excess finding its way into shower operating parts.

7

Image 7
Contents Shower Handbook Contents How your shower works Redring After Sales ServiceDiagram Water too HOT Water goes cold while using showerWater does not flow when button a What to do if things go wrongFixing the shower to the wall Plumbing see diagram Electrical Connections DiagramDiagram Diagram Additional Accessories Catalogue Number How to maintain your showerSpares Chrome Model Accessories Morley WAY, Peterborough PE2 9JJ