SECTION 3
DIAGNOSIS FUNCTION
Description of the Diagnostics function:
1.Setting the Diag display mode
With the power off, press the [4] button, [5]button, and [4] button on the set body or the remote control (for more than 2 seconds) in turn.
4.Contents of each display mode
4-1. Reset count display mode
01 XX
Reset count
(in hexadecimal format)
2.Canceling the Diag display mode
During the Diag function mode, press the [OFF] button.
3.Initial display in the Diag display mode.
Just when the Diag mode is entered, “reset count” is displayed. The display mode is switched by each rotation of
M >/SEEK + or . m/SEEK – keys.
Reset count display
01 XX
Reset count by watchdog timer display
02 XX
Number of connected units display
031 XXX
Operating hours display
Diag code
01: Reset count
4-2. Reset count by watchdog timer display mode
02 XX
Reset count
(in hexadecimal format)
Diag code
02: Number of resets by watchdog timer
4-3. Number of connected units display mode
031 XXX
Show the number of connected units for
Recency of information
Diag code
03: Number of connected unit.
04 XXXX
CD error information display
051 XX
OFFSET/FAILURE error display
061XXXXX
The display mode is switched by each rotation of [2] or [1] keys during the number of connected units display mode.
No. of connected units history 1 (latest) display
031 XXX
No. of connected units history 2 display
032 XXX
No. of connected units history 3 display
033 XXX
4-4. Operating hours display mode
04 XXXX
Operating hours
(in hexadecimal format)
Diag code
04: Operating hours
16