(4) Power Mode
Mode No. | Test Description | Indication value | Remark |
300 | POWER test |
|
|
310 | POWER SUPPLY |
|
|
311 | DC IN | +B voltage value |
|
320 | CHG TEST |
|
|
321 | Charging start |
|
|
322 | BATT under | CHGMNT |
|
|
| voltage value |
|
|
|
|
|
323 | BATT under | +B CHGMNT |
|
|
| voltage value |
|
1.Go into the test mode.
2.Press + key or VOLUME + and VOLUME + and VOL- UME + and VOLUME + in this turn to set the power mode.
4-5. OVERALL ADJUSTMENT MODE (ASSY MODE)
•How to Adjust in Assy Mode
1. Go into the test mode.
2. Press = or VOLUME – key.
XXASSY-M
3.Insert the test CD
4.Press ( key. The system discriminates between CD and MO and performs automatic adjustment for CD.
XX XX POWER
Adjustment value Mode No.
(Lower two digits are displayed.)
3. Press the keys below to change the mode No.
(: Increases the one place. p : Sets the one place to 0.
This key brings the ten place to 0 if the one place is 0.
VOLUME + : Increases the ten place by 10 if the one place is 0. Increases the adjustment value if the one place is
VOLUME
Note) With the mode number 310 selected, pressing ( key will transfer to the mode number (311) for the currently opera- ting power.
With the mode number 300 selected, pressing P key will set the sleep mode. Pressing p key will release it.
• How to Check in the Power Mode
1.For the mode numbers of 311, the voltage of the currently operating power is displayed.
51CD-RUN
Mode No. under adjustment.
• CD Automatic Adjustment
Mode No. | Adjustment Description |
052 | CD EF balance adjustment |
053 | CD ABCD level adjustment |
055 | CD focus gain |
056 | CD tracking gain |
057 | CD focus bias |
5.If the result of automatic adjustment is OK, the following dis- play appears:
(CD) | |
|
|
(MD) |
6.If the result of automatic adjustment is NG, the following dis- play appears:
XX XX
Result of adjustment
NG mode No. (lower two digits)
XX XX MD-OK
– 15 –