Sony MZ-R37 Section Electrical Adjustments, Precautions for Adjustment, Laser Power Check, TDYS-1

Page 17

Ver 1.4 2001. 01

SECTION 5

ELECTRICAL ADJUSTMENTS

PRECAUTIONS FOR ADJUSTMENT

1)Perform all adjustments in the order given in the test mode. After adjusting, exit the test mode.

2)Use the following tools and measuring instruments.

• Test CD

TDYS-1

 

(Part No. : 4-963-646-01)

SONY MO disc available on the market

Laser power meter LPM-8001

(Part No. : J-2501-046-A)

Oscilloscope (Frequency band above 40 MHz. Perform the calibration of probe first before measuring.)

Digital voltmeter

3)Unless specified othewise, supply DC 4.5V from the DC IN 4.5V jack.

4)Swtich, knob positions HOLD switch .............. OFF AVLS switch ................ NORM

LASER POWER CHECK

Connection :

laser

power meter

Optical pick-up objective lens

digital voltmeter

MAIN board

AP5117 (VCC)

AP574 (LDI0)

Adjustment Method :

1.Set the servo mode of the test mode (Mode : 000).

2.Press the ( key, and set the laser power adjustment mode (Mode : 020) using the VOLUME + or – key.

3.Press the =key and move the optical pick-up to the inner most circumference.

4.Open the cover and set the laser power meter on the objective lens of the optical pick-up.

5.Press the ( key, and set the laser CD/MO read adjustment mode (Mode : 021).

6.Check that the laser power meter reading is 0.85 ± 0.085 mW.

7.Check that the voltage between AP5117 (VCC) and AP574 (LDI0) at this time is below 40 mV.

8.Press the ( key, and set the laser MO write adjustment mode (Mode : 022).

9.Check that the laser power meter reading is 6.8 ± 0.68 mW.

10.Press the Pkey to finalize the adjustment data.

11.Check that the voltage between AP5117 (VCC) and AP574 (LDI0) at this time is below 80 mV.

12.Press the pkey.

13.Exit the test mode.

MO TRAVERSE ADJUSTMENT

Connection :

oscilloscope

MAIN board

SP526 (TE)

AP503 (VC)

Adjustment Method :

1.Set the servo mode of the test mode (Mode : 000).

2.Press the ( key, and set the MO test adjustment mode (Mode

: 030) using the VOLUME + or – key.

3.Press the =or + key and move the optical pick-up to the center circumference.

4.Insert any MO disk available on the market.

5.When the ( key is pressed, the MO read EF balance adjust- ment mode (Mode : 032) will be set after MO focus search adjustment mode (Mode : 031).

6.Press the Pkey to perform automatic adjustment, and check that the traverse waveform is symmetrical at the top and bottom.

7.Slide the REC key and set the MO write EF balance adjust ment mode (Mode : 034).

8.Press the Pkey to perform automatic adjustment, and check that the traverse waveform is symmetrical at the top and bottom.

(Traverse waveform)

A

0 V

 

 

C

 

 

 

 

 

 

 

 

B

Specification : A = B, C >= 1.0 Vp-p

9.Check that the traverse level at this time is above 1.0 Vp-p.

10.Press the pkey.

11.Exit the test mode.

Note) Using a recorded disk in this adjustment will erase the data.

Adjustment Location : See page 19.

Adjustment Location : See page 19.

– 17 –

Image 17
Contents MZ-R37 SpecificationsBattery operation time1 Flexible Circuit Board RepairingServicing Note General Test Mode Setting Section SELF-DIAGNOSTICOperation in Test Mode Setting Releasing the Test ModeDescription of Error Indication Codes Clearing the Error Indication Code and Total Recording TimeProblem Indication code Meaning of code Description Description of History Codes History code numberPanel SV ASSY, Front Section DisassemblyPANEL, Bottom LCD Module ConnectorPanel SV ASSY, Upper Main BoardOP Block Assy Cabinet SV AssyHolder Assy Manual Mode Test ModeTest Mode Structure Audio Mode How to Transfer in the Audio Mode System Gain ModeHow to Check in the Mechanism Mode How to Adjust in the Audio ModeHow to Check in the Audio Mode Power Mode Mode No Test Description Indication value Remark Overall Adjustment Mode Assy ModeHow to Adjust in Assy Mode How to Check in the Power ModeMode No Adjustment Description Hybrid MODE, KEY Check ModeMO Automatic Adjustment Precautions for Adjustment Section Electrical AdjustmentsLaser Power Check MO Traverse AdjustmentLOW Reflection CD Traverse Adjustment RF waveform CD RF Level CheckIC PIN Descriptions Section DiagramsFili AvssFilo XlrfSDI2 ClkcsSDO2 SCK2KEY3 LCD ResetKEY2 KEY1MZ-R37 Block Diagram Servo SectionControl B Keyrmc Block Diagram System Control SectionAudio SectionSemiconductor Location Printed Wiring BoardWaveforms IC801 $¼ MZ-R37 IC303 AN7535SA-E1 IC Block Diagrams IC301 AK4517-VQ-LIC304 IC802 8110ANP-DSB-T2IC803 AK6420AM-E IC761 BA6966FV-E2IC901 MPC18A35FTA Panel Section Section Exploded ViewsCabinet SV Assy Section 59 4-216-592-01 Terminal A, Battery DetectionMotor Block ASSY, Sled Sled Mechanism Deck Section MT-MZR37-161MOTOR, DC Loading Main Electrical Parts ListSection Diode TantalumElect Chip RN5RZ25AA-TR Metal ChipCXA2523AR CXD2652ARDescription Remark R202 218-875-11 SWITCH, Slide Synchro REC SwitchSWITCH, KEY Board Display Accessories & Packing MaterialsADAPTOR, Conversion 2P Accessories & Packing MaterialsADAPTOR, AC AC-E455A Corrections Table of Contents Printed Wiring BoardSchematic Diagram Side a Printed Wiring Board Except US ModelMain Board Printed Wiring Board US Model Location SemiconductorMZ-R37 IC801 r Schematic Diagram Main /3MZ-R37 Electrical Parts List CAP-CHIP JFJ7001 Line in Optical Diode MA8140-M-TXJack PHONES/REMOTE Transistor XP4313-TX.SORES-CHIP Filter FILTER, Chip EMI Common ModeNetwork Resistor OP Service Assy Electrical Parts LIST/MISCELLANEOUS Incorrect CorrectIncorrect Correct Head ASSY, OP