Sierra Wireless 20070914 manual Friends, TELNETTIMEOUT=n, =minutes, TPORT=n, Tquit

Page 129

Raven 1x

*SNTPADDR=[d.d.d.d][name]

SNTP Server IP address, or fully‐qualified domain name, to use if *SNTP=1. If blank, time.nist.gov is used.

d.d.d.d=IP address

name=domain name

*TELNETTIMEOUT=n

Telnet port inactivity time out. By default, this value is set to close the AT telnet connection if no data is received for 2 minutes.

n=minutes

*TPORT=n

Sets or queries the port used for the AT Telnet server. If 0 is specified, the AT Telnet server will be disabled. The default value is 2332.

n=0 : Disabled.

n=1‐65535

Tip: Many networks have the ports below 1024 blocked. It is recom- mended to use a higher numbered port.

*TQUIT

Disconnects the telnet session. Not available in AceManager..

Friends

Friends Mode can limit access to the Raven from the cellular network and the Internet. Friends mode is a basic firewall.

Caution: If you are using Friends Mode you will not be able to use AceManager remotely or Telnet to the modem unless you are contacting the modem from one of the configured IP addresses.

Note: Friends Mode will only prevent the Raven modem from receiving data from those IP addresses not on the Friends List. It cannot prevent data, such as pings, from traversing the network to the modem which may billable traffic even though the modem does not receive the data.

 

 

 

 

 

 

 

124

 

 

 

 

 

20070914

 

 

 

Image 129
Contents User Guide Important Notice Safety and Hazards Limitation Liability Qualcomm 3G Patents Copyright TrademarksContact Information Support@sierrawireless.comRevision Release Changes Number Date Revision HistoryContents Configuring your Raven Configuring Modbus/BSAP Contents Contents Contents Circuit Switch Communications Aleos Introduction to the RavenAceManager AceWareMonitor and Control Simplified DeploymentAceNet AceViewNetwork Monitoring Modem Doctor Setup WizardModem Doctor Modem Doctor USBSteps of a connection Connecting to the Telus NetworkDynamic vs. Static IP Addresses Connecting to the InternetSecurity 1x CommunicationSpecifications Interface Port Pin-Outs Power ConnectorSetup Wizard Starting the Setup WizardActivating your Raven on the 3 Telus Network Setup Wizard Connecting to the ModemSelecting Tasks Setup Wizard ConnectedAleos Update OptionalUpdate AleosActivate Modem Setup Wizard Activation CodeSetup Wizard MDN and MIN/MSID Setup Wizard Signal Test Test Modem Setup10 Setup Wizard DUN driver Optional Setting up a DUN Connection12 Setup Wizard DUN connections 14 Setup Wizard DUN Activating Using AT CommandsAT*PROVISION2=MSL,MDN,MIN/MSID,SID,NID Raven 20070914 Mounting Hardware Installation RavenConnecting to Power Indicator Lights Connecting to a Computer or other DeviceLight Patterns MountingOptional Mounting Bracket Hardware Installation of the Raven Rev 3.0B Feb.08 Hardware Installation of the Raven Rev 3.0B Feb.08 Configuring your Raven Using AceManagerStart AceManager AceManager Connect to Modem Connect to your RavenAceManager Connected Enter the configuration optionsUsing Templates Write the changes to the modemCreating the Template with AceManager · Cellular Technology specific settings the CDMA/EV‐DO group Applying a Template to one modem with AceManager Reset the modemConfiguring your Raven 10 AceNet Selected modems Choose a name and icon for your connection Using a Terminal Application with AT CommandsConnect To Port Settings serial only· Flow Control Hardware ConnectedAT Commands Data Communication and Host 6 Modes Basic ModesSerial Modes Start up Mode Basic ModesData Communication AT Mode AceManager PassThru PassThru ModeSerial Modes Telnet ModeAT\APPP UDP Auto Answer UDP and UDP PadReliable UDP TCP and TCP Pad UDP Multicast ModeTCP Auto Answer Hybrid ModesUdplast Data Communication Public and Private ModeKeepalive Data usage using Keepalive Configuring KeepaliveIpping Reasons to contact the modem and/or the connected device IP ManagerUnderstanding Domain Names Dynamic Names Car54.mydomain.comCar54.mydomain.com.ca AceManager Dynamic IP Using IP Manager with your RavenData Usage for IP Manager Server Updates Eairlink.comRestrictions for Modem Name Understanding DNS Configuring DNSAceManager DNS PPP-Peer Domain NameModbus Overview Configuring Modbus/BSAPTelemetry Remote Terminal Unit RTUProgrammable Logic Controller PLC Supervisory Control and Data Acquisition ScadaModbus TCP/IP Raven Modbus on UDPConfigure the listening/device ports Configuring the Raven at Polling Host for Modbus onConfigure IP addresses for the Modbus IDs Configure the default mode for start-upOptional Dynamic IP Address Configure the ports Configuring the Remote Ravens for Modbus with UDPAceManager UDP Configure IP addresses for the hostConfigure other RTU settings AceManager DNS Raven 20070914 Snmp Simple Network Management Protocol Management Information Base MIBSnmp Traps Snmp Configuration Listening PortSecurity Level AceManager Change Password menu option User Name and PasswordSnmp MIB Definition Sample Trap DestinationCommunity String Snmp Simple Network Management Protocol Snmp Simple Network Management Protocol Snmp Simple Network Management Protocol Display Responses Product ID Info information Configuration CommandsNETPHONE? DEVICEID?HOSTMODE? StatusNETCHAN? NETERR?Any other value Failure AT Commands Requiring PassThru mode +GSN +ECIO?+WHWV +WPRL?Common Misc Miscellaneous+++ DS=n Dmethodd.d.d.d/ppppp or Dmethod@name/ pppppOPRG=n S53=methodd.d.d.d/pppppMethod= P UDP Method=T TCP Method=N Telnet =1‐65535 D.d=IP address SerialS3=n S4=nS5=n =0‐255 =2‐10 seconds=1‐2545 Parity=O Odd Parity=E Even Parity=N None Parity=M Mark=tenths of a second S50=nS51=n S211=n\Qn \APPP+IPR=n $QCVAD=nModemhispeed CTSE=nNUMTOIP=n PPPNOCARRIER=nS7=n S0=n=seconds S60=n=interval =0 ‐MDhh HOR=nHh=01 Slip Hh=02 PPP Hh=03 UDP Hh=04 TCP Hh=33 BsapDU=n S83=nUALL=n UDPLAST=nDynamic IP DNSUPDATE=nD.d=IP address of domain server DNSUSER=d.d.d.dDOMAIN=name Name=domain nameIPMGRKEYn=key IPMGRUPDATEn=m PPP/EthernetMODEMNAME=name DHCPSERVER=n HOSTAUTH=nHOSTNETMASK=n.n.n.n String=password PassThruD.d=local or peer IP address of the modem \APASSTHRU String=AT commandsCSX1=n PTINIT=stringPTREFRESH=n RESETPERIOD=n=1‐255 minutes =1‐255 hours=SMS/E‐mail server number Pw= passwordEmail=email address Body=message body SMTPSTATUS?Subject=message subject Cntsms DasmsIndex= index list 0, 1 Message= message number SSMS? OtherDAE=n DATZ=n=15‐255 minutes ResetcfgD.d=IP address Name=domain name Name=domain name Port=port=1 On Host=IP address Port=TCP portFriends TELNETTIMEOUT=n=minutes TPORT=nLogging FM=nD.d = IP address DBGCOMMLVL=n Telemetry/Addr ListDBGIPLVL=n DBGPPPLVL=nMVLEN=n IPL=nMVMSK=hh Hh=hex valueMVOPT=n Addr ListMVTYP=n RKEY=nId=ID D.d=IP address or name 1x/EV-DOHexid=ID D.d=IP address or name +CTA=nNnnnnn=6 digit unlock code ~NAMLCK=nnnnnnPROVISION=MSL,MDN/MIN,SID,NID PROVISION2=MSL,MDN,MIN,SID,NID+WIMI=num +WMDN=numNam=0 Min=phone number Msid=second number Sid=system ID Nid=network IDConfiguring Circuit-Switch Circuit Switch Communications BAT Commands and the Command String Commands Specific to the Raven 1x C3211 Commands Specific to the Raven 1x C3210 and C3216Step by Step Configuration Raven LEDs in Circuit-Switched ModeCommon AT Commands Software Required Hardware RequiredConnect the modem to your computer Erase the internal memoryInformation Required for CDMA/1x only Rev 3.0B Feb.08 139 Start All Programs AirLink Communications AceManager 3G Activate the RavenSave the serial setting Configure serial port speed12 AceManager Disconnect Configure the Raven using a AceManager template15 AceManager Load Configure additional PassThru settingsConfigure the Raven for your equipment Save the configuration settingsReset the Raven Test the Raven ConfigurationCommission the Raven Modem on Site 146 20070914 Install the driver Installing a modem driver for RavenWindows Dial-up Networking C DUN Connect the RavenSelect the Modems tab Check Don’t detect my modem I will select it from a list Check Selected Ports Modem Properties Configure the driverModem Properties Modem Creating a Dial-Up Networking PPP Connection10 Windows Start menu Create a new network connectionSelect Connect to the Internet Select Set up my connection manually Rev 3.0B Feb.08 156 Rev 3.0B Feb.08 157 21 New Connection Finish Configure the DUN connectionCheck Show icon...when connected Rev 3.0B Feb.08 160 Select Advanced Start AceView Connecting to the Internet Using DUNWindows DUN Enable the ConnectionSelect Dial to connect to the modem and the cellular network Start the DUN sessionWindows Dial-up Networking DUN Rev 3.0B Feb.08 165
Related manuals
Manual 176 pages 17.38 Kb Manual 36 pages 19.88 Kb Manual 203 pages 17.49 Kb

20070914 specifications

Sierra Wireless 20070914 is a cutting-edge wireless communication module designed for IoT applications, offering remarkable features and robust performance. This module represents a significant advancement in the realm of embedded wireless solutions, catering to a variety of industries including automotive, industrial automation, and smart cities.

One of the key features of the Sierra Wireless 20070914 is its support for multiple cellular standards, including LTE, which ensures high-speed data transfer and reliable connectivity. The module is designed to operate on various frequency bands, making it versatile and suitable for global deployment. This multi-band capability allows businesses to deploy their IoT solutions in different regions without modification, reducing time-to-market and deployment costs.

Another standout characteristic of the Sierra Wireless 20070914 is its comprehensive and seamless integration with cloud services. The module supports advanced cloud connectivity options, enabling real-time data processing and analysis, which is crucial for industries that rely on timely decision-making. This feature is particularly important in sectors like transportation and logistics, where real-time tracking and monitoring are essential.

The power efficiency of the Sierra Wireless 20070914 is noteworthy. It is engineered to operate optimally in low-power modes, making it ideal for battery-operated devices. This focus on energy efficiency ensures prolonged device lifecycles, supporting the growing demand for sustainable and eco-friendly technologies.

Moreover, the module includes encrypted communication features, enhancing security and protecting sensitive data transmissions. With the increasing prevalence of cyber threats, this security aspect is critical for businesses looking to safeguard their IoT applications from unauthorized access and data breaches.

In addition to these features, the Sierra Wireless 20070914 offers comprehensive development support, including software development kits (SDKs) and application programming interfaces (APIs). This makes it easier for developers to integrate the module into their existing systems, streamlining the development process and accelerating innovation.

Overall, the Sierra Wireless 20070914 stands out as a powerful solution for IoT connectivity, blending advanced technology, security, and efficiency. Its capabilities are designed to support the diverse needs of modern industries, paving the way for future innovations and advancements in wireless communication. As businesses increasingly turn to IoT for modernization, modules like the Sierra Wireless 20070914 will play a crucial role in enabling this transformation.