Vidikron 80 manual About warning indicators, Actions to be taken upon warning indications, For Nos

Page 32

Warning Indication

About warning indicators

If an abnormality occurs in this unit during projection, the warning mode will be triggered and the type of abnormality will be indicated by a combination of indicators displayed on the control panel. This unit will then automatically stop projection and run the cooling fan for about 90 seconds.

No.

 

Indicator

 

Warning

 

[LAMP]

[TEMP]

[STAND BY]

[OPERATE]

 

 

1

Blinking

 

Blinking

 

Lamp does not light up and unit is unable to project

2

Blinking

Blinking Simultaneously

Blinking

Lamp turned off during projection

 

 

 

 

 

Lamp usage time has exceeded 2010 hours

3

Blinking

Blinking

 

 

Circuits are not functioning properly (Circuit Operation Error)

4

Blinking

Blinking Alternately

Blinking

Lamp cover is not installed

5

 

Blinking

 

 

Internal temperature is abnormally high (Internal Temperature Error)

6

 

Blinking

Blinking

 

Temperature at air inlets are high (External Temperature Error)

7

Blinking

Blinking

Blinking

Blinking

Inner fan has stopped (Fan Locked)

• For details on individually blinking indicators, please refer to Page 13.

Actions to be taken upon warning indications

Please follow the procedures below.

For Nos. 1-3

No. 1: Perform procedures to turn on/off the power again.

No. 2: After checking if an impact shock has not occurred during operation, perform procedures to turn on/off the power again. When the warning on lamp time is displayed, remove the power plug when the [STAND BY] indicator is still on, followed by installing a new lamp.

No. 3: Perform procedures to turn on/off the power again.

For Nos. 4-7

Remove the power plug when the [STAND BY] indicator is on. After that, check No. 4 - No. 7.

No. 4: Ensure that the lamp is correctly mounted into this unit. Next, ensure that the lamp cover is correctly mounted. After that, re- start according to the basic operation procedures.

No. 5: Check that nothing is blocking the air inlets, and wait until the inside cools down. After that, restart according to the basic operation procedures.

No. 6: Check the ambient temperature. If it is normal, leave the unit until it cools down. After that, restart according to the basic opera- tion procedures.

No. 7: Leave the unit until it cools down. After that, restart according to the basic operation procedures. If the warning indication is displayed again, wait for the cooling fan to stop. Check that the [STAND BY] indicator is on, followed by removing the plug from the power outlet. Call your authorized dealer for repair.

32

Image 32
Contents ILA Projector Table of Contents Features You’ll enjoy include Contents of the packageIntroduction OptionsSafety Precautions About the installation placeFCC Information U.S.A. only Machine Noise Information Germany onlyDo not allow any unqualified person to install the unit Safety Precautions Power Connection This Apparatus Must be GROUNDED. ImportantEnvironment of Use Maintenance ProceduresAbout Burning-in of D-ILA Device Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Controls and Features Projector Chassis CoverTo Open the Projector Cover To Close the Projector CoverConnector Panel Service TerminalSync OUT Terminal RS-232C Terminal D-sub 9 PinControls and Features Control Panel on the Projector Lamp IndicatorIndicator Display on the Control Panel About Cool Down ModeControls and Features Remote Control Installing the Projector Precautions for InstallationInstallation Environment Precaution for UsageMounting the Unit on a Ceiling Installing the Projector Projector and Screen InstallationPrecautions for Ceiling-mount Throw Distance Chart Screen Size and Projection DistanceWhen reflecting off a screen When directing remote control unit toward this unitConnecting to Various Devices Connecting to DevicesConnecting to the VDP-80 digital video processor Control from an external automation devicePage Turning on the power Adjusting ZoomAdjusting Focus Basic OperationPress Mute Pull out the power plug from the power outletBasic Operation Hiding the image temporarily Adjustments and Settings Using Menus Menu StructureAdjustments and Settings Using Menus Menu Operation Buttons FunctionProcedures for Menu Operation After setting is completed, press ExitPress the Menu button Press 5/6 to select a main menu item and Enter to confirmAdjustments and Settings Using Menus Screen Blanking Project image onto the screenPress 5/6 to select Projector Opt, followed by pressing Press the Menu button to endShift Setting Press 5/6 to selectOptions, followed by pressing Enter Replacing the Lamp For service personnel only Resetting Lamp Time When the lamp usage time exceeds 2010 hours Lamp and Lamp Usage TimeCleaning and Replacing the Filter What to do when these messages are displayed MessageAbout warning indicators Please follow the procedures belowActions to be taken upon warning indications For NosTroubleshooting SymptomRS-232C Terminal DVI Terminal Terminal DescriptionPin Arrangement Communication Specifications Command FormatRS-232C External Control External control command table Terminal DescriptionParameters used for the data format Numeric valueSpecifications Dimensions Page RUMA-011080 Version
Related manuals