AT&T 555-600-736 manual Module LINE/TRUNK Station Type Specifications

Page 33

-31-

LEGEND SYSTEM CONTROL UNIT MODULES

 

MODULE

LINE/TRUNK

STATION TYPE

SPECIFICATIONS

 

 

 

TYPE

 

 

 

 

 

 

 

 

 

 

008

n/a

Analog multiline

Capacity: 8 analog stations

 

 

 

 

telephone; Call

Signaling: analog multiline

 

 

 

 

Management System;

telephone protocol (40 kbps)

 

 

 

 

analog data with

Loop range: 1000 ft in-building

 

 

 

 

a general purpose

or in-range out-of-building

 

 

 

 

adapter

with analog IROB protectors)

 

 

 

 

 

service only

 

 

008 MLX

n/a

MLX telephone; digital

Capacity: 8 digital stations,

 

 

 

 

data service (the

each with 1 or 2 endpoints.

 

 

 

 

ISDN 7500B Data

including the following station

 

 

 

 

Module)

types:

 

 

 

 

 

*digital voice only

 

 

 

 

 

*digital voice with Voice

 

 

 

 

 

Announce to Busy

 

 

 

 

 

*digital voice and digital data

 

 

 

 

 

(via ISDN 7500B Data Module)

 

 

 

 

 

*digital voice and MFM

 

 

 

 

 

*digital data only (ISDN 7500B

 

 

 

 

 

Data Module)

 

 

 

 

 

Signaling: ISDN-BRI S/T

 

 

 

 

 

protocol (2 64-kbps B channels,

 

 

 

 

 

one 16-kbps D channel), on a

 

 

 

 

 

passable bus.

 

 

 

 

 

Power: 48-VDC phantom power to

 

 

 

 

 

telephone: 48 VDC over a separate

 

 

 

 

 

pair (7-8) to an operator DSS console

 

 

 

 

 

Loop range: 1000 ft. in-building

 

 

 

 

 

and in-range out-of-building (with

 

 

 

 

 

MLX IROB protectors) service only

 

 

 

 

 

 

 

 

008 OPT

n/a

on-premises or off-

Capacity 8 T/R stations on

 

 

 

 

premises single-line

2-way voice transmission path

 

 

 

 

telephone

with support for telephones with

 

 

 

 

 

message-waiting LEDs: 2 TTRs

 

 

 

 

 

Ringing current: 105-Vrms.

 

 

 

 

 

30-HZ sinusoidal ringing super-

 

 

 

 

 

imposed cm -48 VDC; a ring

 

 

 

 

 

generator must be installed in

 

 

 

 

 

the power supply module of each

 

 

 

 

 

carrier that has a 008 OPT module.

 

 

 

 

 

REN: <1.0 per port

 

 

 

 

 

.

 

 

 

 

 

Disconnect signal: 900 ms

 

 

 

 

 

(T/R short for answering machines,

 

 

 

 

 

G3 Fax, etc.)

 

 

 

 

 

Switchhook flash detection

 

 

 

 

 

300-1200 ms

 

 

 

 

 

Loop Resistance: Serves 2-wire

 

 

 

 

 

loops to 1300 ohms, including

 

 

 

 

 

stations

 

 

 

 

 

Notice to Telco: Meets FCC

 

 

 

 

 

Class c

 

 

 

 

 

 

 

Image 33
Contents AT&T Merlin Legend Communications System Application Notes Page Merlin Legend Trunking Concepts Application Note Index TIP and Ring Explained Introduction to Trunking ConceptsLines and Trunks LOOP-START Trunks Operations Problem of Glare LOOP-START Trunks POTENTIAL-PROBLEMSAutomated Attendant Ghost Calls and Loop-Start Facilities LOOP-START Trunks When to USE LOOP-START Trunks Proper Loop-Start Facility ApplicationsUnavoidable Loop-Start Facility Applications Cost GROUND-START Trunks Operations GROUND-START Trunks When to USE GROUND-START Trunks GROUND-START Trunks Potential ProblemsDirect Inward Dialing did Trunks Operational Characteristics Types of Loop Reverse-Battery Signaling Did Trunk Signaling CharacteristicsAdministration Considerations in Using did Trunks When to USE did Trunks TIE TrunksSimple Tie Trunk Operation Tandem Tie Trunk Operation Signaling and Implementation TIE LinesTransferring Calls P E Transmit C E I V E ON-HOOK OFF-HOOK OFF Premises Stations Page Overview and Operations DS1 ServicePotential Problems/Limitations DESIGN, Signaling & ImplementationDo GBS Customers Need T-1? Data Communications EquipmentChannel Service Unit CSU Multiplexer MUX Isdn DS1 Facility ServicesSDN SID/ANI Maintenance and Troubleshooting Special HOTEL/MOTEL TrunksOperation Overview Hardware Module LINE/TRUNK Station Type Specifications TTR Trunk analog voice Reusable Modules from Merlin II R3 Considerations AdministrationReferences