Avocent EMS1000P To Display the Supplied Skew Test Pattern, To Zero the Skew Adjustment Dials

Page 34

26Emerge EMS Installer/User Guide

To Display the Supplied Skew Test Pattern

1.Insert the supplied Avocent CD-ROM into the CD player of the computer.

2.Within Windows, use the My Computer option (usually available as a desktop icon or within the Start menu) to view the contents of the CD-ROM. Double-click the Skew entry to display the standard test pattern. If necessary, maximize the application window so that the image fills the screen.

The screen will show a series of fine red, green and blue crosses which should all be in line, vertically and horizontally- skew affects the horizontal placement of the colors.

Figure 3.6: The supplied skew test pattern showing green slightly retarded relative to the red and blue

To Zero the Skew Adjustment Dials

When supplied, the two skew dials are set in their neutral positions. i.e. no delay to either of its colors. However, if the unit has been previously used and adjusted then you may need to relocate the zero point. There are no setting markers around the two skew dials and the dial itself does not have a pointer.

1.Insert a small screwdriver into the skew dial and twist it all the way counterclockwise. Note the position of the dial when it reaches its end point.

2.Rotate the screwdriver fully clockwise and again note the endpoint position of the dial.

3.Now rotate the screw driver counterclockwise until the dial reaches the position that lies midway between the two end points. This is the neutral position.

4.Repeat this procedure for the other skew dial, if necessary.

0

(no compensation)

MaxMax

Figure 3.7: A skew compensation dial showing its middle neutral position and its two maximum positions

Image 34
Contents Emerge EMS Instructions Emerge EMS European approvals European EMC directive 89/336/EECTable of Contents Iv Emerge EMS Installer/User Guide List of Figures Vi Emerge EMS Installer/User Guide Features and Benefits Configuration PossibilitiesEmerge EMS Installer/User Guide Transmitter Cascading Further ExpansionReceiver Cascading Safety Precautions Installation LocationsUsing the rear mounting slot Using the supplied self adhesive feetMounting Using the optional rack mount chassis Connections at the Transmitter Making Standard ConnectionsTo Connect Video and Audio from the Source PC System Connecting a monitor and speakers to the transmitter unit To Connect a Monitor and SpeakersTo Connect the Link Cables Emerge EMS1000P modelsEmerge EMS1000MP-T models To Connect the Power Adaptor Connecting the power adaptor to the transmitter unitConnections at the Receiver To Connect Displays and Speakers13 Connecting the link cable to the receiver unit Link14 Connecting the power adaptor to the receiver unit Important Limitations When Cascading Emerge EMS units Making Cascade ConnectionsCascade connection examples Cascade17 Connecting multiple transmitters in a cascade arrangement Cascading TransmittersTo Connect Cascaded Transmitters Video Image Adjustments Cascading Receivers Emerge EMS1000MP-R Receivers OnlyTo Connect Cascaded Receivers Emerge EMS Installer/User Guide Indicators OperationsTo Adjust Brightness and/or Sharpness AdjustmentsBrightness and Sharpness Adjustments To Display a Suitable High Contrast ImageTo Create a Skew Test Pattern Creating a suitable skew test pattern within a paint packageTo Zero the Skew Adjustment Dials To Display the Supplied Skew Test PatternTo Adjust Skew Emerge EMS Installer/User Guide To resolve an issue Appendix a Technical SupportAppendix B Troubleshooting No video image is received at the receiver unitD E Emerge EMS Installer/User Guide 092705-00UG
Related manuals
Manual 2 pages 58.13 Kb

EMS1000P specifications

The Avocent EMS1000P is a robust and versatile environmental monitoring solution designed to ensure optimal operational integrity for data centers and critical infrastructure. Engineered to deliver performance and reliability, the EMS1000P addresses the growing need for effective environmental management in today's tech-heavy environments. It is a pivotal asset for IT managers looking to safeguard equipment while maximizing uptime.

One of the standout features of the EMS1000P is its advanced temperature and humidity monitoring capabilities. With multiple sensor inputs, the device can precisely measure and report environmental conditions, alerting users to any anomalies that may pose risks to equipment and operations. By maintaining an optimal climate, users can prevent equipment failures and extend the lifespan of sensitive electronics.

The EMS1000P integrates seamlessly with various monitoring systems and software, providing users with a centralized platform to visualize and manage environmental data. It supports SNMP for easy integration with existing network management tools, ensuring comprehensive oversight of environmental metrics. The device is equipped with customizable alerts, enabling administrators to receive notifications via email or SMS when conditions exceed predefined thresholds.

Additionally, the EMS1000P features a user-friendly web interface, making it easy to configure settings, access historical data logs, and generate reports for proactive monitoring. This streamlined access promotes efficient decision-making and real-time responses to potential issues.

Power consumption is another critical factor in data center operations, and the EMS1000P contributes to energy efficiency by allowing monitoring of power usage and environmental conditions. This insight helps organizations make informed choices about energy consumption, thereby reducing operational costs and carbon footprint.

The rugged design and compact form factor of the EMS1000P make it suitable for installation in various environments, including server rooms, telecommunications facilities, and other mission-critical locations. Its reliability and scalability make it an ideal solution for businesses looking to enhance their environmental monitoring capabilities.

In summary, the Avocent EMS1000P is a comprehensive environmental monitoring solution that combines advanced sensor technology, seamless integration, and user-friendly features. Its ability to monitor temperature, humidity, and power usage ensures that critical infrastructure remains efficient and protected, solidifying its value for modern IT operations. The EMS1000P is more than just a monitoring device; it is a crucial component in maintaining the health of an organization’s IT ecosystem.