MAINTENANCE AND TROUBLE-SHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department toll- free at
1.SYMPTOM: THE POWER DOES NOT TURN ON
a.Make sure that the power cord is plugged into a surge protector, and that the surge protector is plugged into a properly grounded outlet. (See HOW TO PLUG IN THE POWER CORD on page 7.) Use only a
b.After the power cord has been plugged in, make sure that the key is fully inserted into the console. (See step 3 on page 9.)
c. Check the circuit breaker located on the treadmill near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.
d. Check the on/off switch located at the front of the treadmill near the power cord. The switch must be in the on position.
2. SYMPTOM: THE POWER TURNS OFF DURING USE
c |
|
Tripped | Reset |
d |
|
On |
|
Position |
|
a. Check the circuit breaker located on the treadmill frame near the power cord (see 1. c. above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.
b. Make sure that the power cord is plugged in.
c. Remove the key from the console. Reinsert the key fully into the console. (See step 3 on page 9.)
d. Make sure that the on/off switch is in the on position. (See 1. d. above.)
e. If the treadmill still will not run, please call our Customer Service Department,
3.SYMPTOM: THE WALKING BELT SLOWS WHEN WALKED ON
a.Use only a
b.If the walking belt still slows when walked on, please call our Customer Service Department,
4.SYMPTOM: THE WALKING BELT IS OFF-CENTER WHEN WALKED ON
a. If the walking belt has shifted to the left, first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left adjustment bolt clockwise 1/4 of a turn. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.
a |
18