PROBLEMSOLUTION
7.The handgrip pulse sensor does not func- tion properly
a.Make sure to stand on the foot rails and avoid moving your hands while mea- suring your heart rate. Excessive movement may interfere with heart rate read- ings. If the handgrip pulse sensor is not used correctly, your heart rate will not be shown.
b.Do not hold the metal contacts too tightly; doing so may interfere with heart rate readings.
c.For the most accurate heart rate reading, hold the contacts for about 15 seconds.
d.For optimal performance of the handgrip pulse sensor, keep the contacts clean. The contacts can be cleaned with a soft
8.The chest pulse sen- sor does not function properly
a. If the chest pulse sensor does not function properly, see CHEST PULSE SENSOR
b. If the chest pulse sensor still does not function prop- |
|
|
|
|
erly, the battery should be changed. To replace the |
| Battery Cover |
| |
battery, locate the battery cover on the back of the |
|
|
|
|
|
|
|
| |
sensor unit. Insert a coin into the slot in the cover and |
|
|
|
|
turn the cover counterclockwise to the “open” position. |
|
|
|
|
Remove the cover. |
|
|
|
|
|
|
|
|
|
Remove the old battery from the sensor unit. Insert a new CR 2032 battery, making sure that the writing is on top. In addition, make sure that the rubber gasket is in place in the sensor unit. Replace the battery cover and turn it to the closed position.
Battery
Cover
Battery
Rubber
Gasket
27