Table 1—ICM FIOP Physical Data—Unit 48GP

THIS DATA APPLIES TO 48GP UNITS WITH THE ICM INDOOR MOTOR FIOP

UNIT SIZE 48GP

024040

024060

030040

030060

 

036060

036090

042060

042090

NOMINAL CAPACITY (ton)

2

2

2-1/2

2-1/2

 

3

3

3-1/2

3-1/2

OPERATING WEIGHT (lb.)

290

290

313

313

 

321

321

382

382

COMPRESSORS

 

 

 

Scroll

 

 

 

Quantity

 

 

 

 

1

 

 

 

REFRIGERANT (R-410A)

5.0

5.0

5.5

5.5

 

6.9

6.9

9.0

9.0

Quantity (lb.)

 

 

 

 

 

 

 

 

 

 

REFRIGERANT METERING DEVICE

 

 

 

 

 

 

 

 

 

Orifice ID (in.)

.057

.057

.057

.057

 

.065

.065

.070

.070

AccuRater™ Piston

 

 

 

 

 

 

 

 

 

CONDENSER COIL

1...17

1...17

1...17

1...17

 

2...17

2...17

2...17

2...17

Rows...Fins/in.

 

10.9

10.9

12.7

12.7

 

9.1

9.1

12.3

12.3

Face Area (sq ft)

 

 

 

 

 

 

 

 

 

 

CONDENSER FAN

2350

2350

2350

2350

 

2350

2350

2350

2350

Nominal Cfm

 

22

22

22

22

 

22

22

22

22

Diameter (in.)

 

1/8 (825)

1/8 (825)

1/8 (825)

1/8 (825)

 

1/8 (825)

1/8 (825)

1/8 (825)

1/8 (825)

Motor HP (Rpm)

 

 

 

 

 

 

 

 

 

 

EVAPORATOR COIL

3...15

3...15

3...15

3...15

 

3...15

3...15

3...15

3...15

Rows...Fins/in.

 

3.7

3.7

3.7

3.7

 

3.7

3.7

4.7

4.7

Face Area (sq ft)

 

 

 

 

 

 

 

 

 

 

EVAPORATOR BLOWER

800

800

1000

1000

 

1200

1200

1400

1400

Nominal Airflow (Cfm)

 

10 X 10

10 X 10

10 X 10

10 X 10

 

11 X 10

11 X 10

11 X 10

11 X 10

Size (in.)

 

1/2

1/2

1/2

1/2

 

3/4

3/4

3/4

3/4

Motor (HP)

 

 

 

 

 

 

 

 

 

 

FURNACE SECTION*

 

 

 

 

 

 

 

 

 

Burner Orifice No. (Qty...Drill Size)

2...44

2...38

2...44

2...38

 

2...38

3...38

2...38

3...38

Natural Gas

 

2...50

2...46

2...50

2...46

 

2...46

3...46

2...46

3...46

Burner Orifice No. (Qty...Drill Size)

 

 

 

 

 

 

 

 

 

 

Propane Gas

 

 

 

 

 

 

 

 

 

HIGH-PRESSURE SWITCH (psig)

 

 

 

610 ± 15

 

 

 

Cutout

 

 

 

 

 

 

 

 

 

420 ± 25

 

 

 

Reset (Auto)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOSS-OF-CHARGE/LOW-

 

 

 

 

 

 

 

 

 

PRESSURE SWITCH

 

 

 

20 ± 5

 

 

 

(Liquid Line) (psig)

 

 

 

 

 

 

 

 

 

45 ± 10

 

 

 

Cutout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset (Auto)

 

 

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)

20 X 20 X 1

20 X 20 X 1

20 X 20 X 1

20 X 20 X 1

 

20 X 24 X 1

20 X 24 X 1

24 X 30 X 1

24 X 30 X 1

Throwaway

 

 

 

 

 

 

 

 

 

 

* Based on altitude of 0 to 2000 ft.

cooling cycle remains ‘‘on’’ until the room temperature drops to point that is slightly below the cooling control setting of the room thermostat. At this point, the thermostat ‘‘breaks’’ the circuit between thermostat terminal R to terminals Y and G. These open circuits de-energize contactor coil C and ICM board. The con- denser and compressor motors stop. After the time delay setting selected on the Easy Select™ board (See Easy Select Section) , the blower motor stops. The unit is in a ‘‘standby’’ condition, waiting for the next ‘‘call for cooling’’ from the room thermostat. The 5 minute compressor delay also applies to heat pump heating mode.

ELECTRICAL DATA & SCHEMATICS—ICM FIOP

Step 1—Physical Data & Electrical Schematics

Use the Physical Data and Electrical Tables on the following pages for information that applies to Carrier Puron® units with the ICM indoor motor FIOP.

AIRFLOW & TEMPERATURE RISE TABLES—ICM FIOP Step 2—Tables For System Set-Up

Use the Airflow and Temperature Rise Tables on the following pages for information that applies to Carrier Puron® units with the ICM indoor motor FIOP.

CARE AND MAINTENANCE

Indoor Blower and Motor

NOTE: All motors are pre-lubricated. Do not attempt to lubricate

these motors. For longer life, operating economy, and continuing efficiency, clean accumulated dirt and grease from the blower wheel and motor annually.

Disconnect and tag electrical power to the unit before cleaning and lubricating any blower motor and wheel. On units with gas heat, turn off the gas supply before disconnect- ing the electrical power. Failure to adhere to this warning could cause serious injury or death.

To clean the blower motor and wheel:

1.1. Remove and disassemble blower assembly as follows:

a.Remove unit access panel.

b.Carefully pivot blower access panel outward towards the electrical box. Route wiring above blower access panel.

c.Disconnect the 5 and 16 pin plugs at the blower motor.

d.On all units, remove blower assembly from unit. Remove screws securing blower to vertical partition and slide assembly out. Be careful not to tear insulation in blower compartment.

e.Ensure proper reassembly by marking blower wheel and motor in relation to blower housing before disassembly.

12

Page 12
Image 12
Carrier 50GL 024-060, 48JZ (N) 024-060, 48GP (N) 024-060, 50JZ 024-060 operating instructions ICM Fiop Physical Data-Unit 48GP

48JZ (N) 024-060, 50JZ 024-060, 48GP (N) 024-060, 50GL 024-060 specifications

The Carrier 50GL 024-060, 48GP (N) 024-060, 50JZ 024-060, and 48JZ (N) 024-060 units are part of Carrier’s advanced HVAC solutions, offering efficient cooling and heating systems designed for both residential and light commercial applications. These models are known for their reliability, energy efficiency, and innovative technology, making them a popular choice for users looking to enhance comfort while reducing operational costs.

One of the main features of the Carrier 50GL series is its use of high-efficiency compressors. These compressors are engineered to operate quietly and effectively, providing optimal performance even during peak load conditions. Additionally, they are equipped with smart features that allow for precise temperature control and improved energy savings, often exceeding standard performance metrics.

The 48GP (N) units are particularly notable for their compact design, making them ideal for installations where space is a limitation. Despite their smaller footprint, they boast significant cooling and heating capacities, ensuring consistent comfort. The use of advanced variable-speed technology in these units helps to maintain consistent indoor temperatures while minimizing energy consumption.

The 50JZ and 48JZ (N) models incorporate advanced inverter technology, allowing for variable refrigerant flow. This technology adjusts the system's output according to the demand, resulting in lower energy usage and increased comfort levels. Additionally, these units feature enhanced filtration systems that improve indoor air quality by capturing airborne pollutants, allergens, and other contaminants.

Another key characteristic of these Carrier units is their durability. Built with high-quality materials, they are designed to withstand harsh environmental conditions, ensuring longevity and reduced maintenance requirements. Furthermore, the installation process is simplified, thanks to user-friendly design features that promote easy serviceability and accessibility.

Overall, the Carrier 50GL 024-060, 48GP (N) 024-060, 50JZ 024-060, and 48JZ (N) 024-060 HVAC units stand out in the industry for their advanced features, energy efficiency, and robust performance. They offer a comprehensive solution for anyone seeking reliable temperature control and improved indoor air quality in a variety of settings.