Soehnle 3030 Quantity check special character, Displaying the setpoint and tolerance, Startmode

Page 27

English

Switch between part and percent by pressing the function change key F>. If you wish to define

the plus and minus tolerances separately, activate the "+/- tolerance separate" function in Setting mode.

The display switches to the Count display view. The special characters are activated.

The relevant special character is displayed next to the setpoint depending on the actual weight on the scale.

Quantity check special character

under tolerance point

within tolerance

Setpoint exactly reached

over tolerance point

You can also display the difference between actual values and setpoint weights at the top left of the additional display in figures with a + or - sign. Activate the additional display by pressing F3 Unit in Level 4 Setting Functions.

If you activated a memory location containing setpoints and tolerances in the Ref Fixed memory, the special characters are activated automatically.

A totalising/batching operation (accept in the total memory by pressing the Plus key) interrupts the display of the quantity check special character until the scale is clipped off. The quantity check special character is then reactivated.

Displaying the setpoint and tolerance

Press the Info key and then F3 "Quant. Check" or press the "Quant. Check" key in Level 2 Checking Functions. The current values then appear in the display box.

Switching points for quantity check

See the description of the function in the CD manual.

Data record/Printout within or outside the tolerance

You can inhibit or accept release of a data record if it is outside a specific tolerance band. If a data record is released outside a tolerance, it is marked by a special

character.

The function is released or inhibited in Setting mode (see manual).

Startmode

When Start mode is activated, the scale freezes the switching point after the switching point is reached. The scale can then be clipped off without deactivating the switching point, thus preventing the start of an undesired new operation. Only after you press F6 Start is the freeze state cancelled.

Activate Start mode in Setting mode (see manual).

27

Image 27
Contents 3030 English ContentDescription of the appliance Technical dataOperating concept, keys and display symbols Installation and commissioningNavigation with the function keys Programming modeCancel Function keysDisplay Input and control keysSymbol for standstill Symbols in the display Symbol bar Information panePower on/off Basic functionsSelecting a program Zeroing X10 displayGross display Content input Organisation data identifiersDescription input Unit Switching between scalesManual switchover Automatic switchoverActivating input boxes Input procedure Numerical boxesAlphanumeric input Types of input boxSelecting an application program Application programsWeighing and taring Function keysDisplay view Weighing without taring Manual taringTaring by manual tare input Automatic taring Multiplicative tareAdditive tare Provisional tareDisplay options with the Info key Error message when taring1st level totalising functions 3rd level setting functionsTotalising and batching Total memory with several connected scalesF5 Manual TaringOperating the totalising functions F6 PlusAssigning and clearing the consecutive number Clip off factor when totalisingSelection options for total display Automatic totalisingPiece counter Print keysDisplaying the current totals Displaying individual pieces 2nd level checking functions 4th level setting functionsCounting 1st level counting functionsFunction key F2 Ref Variab Counting display viewCounting function Function key F1 RefFixed value memory for reference weights New reference weightDisplaying the reference weight Weight display during count operationCalling the list of reference weights for counting Quantity checkTotalising different countable parts Data record/Printout within or outside the tolerance Switching points for quantity checkQuantity check special character Displaying the setpoint and toleranceCounting with several weighing platforms 1st level checking functions CheckingCheck special characters Check display viewChecking functions Type in setpointsNew setpoint Terminating the checking functionFixed value memory for setpoints Switching points for checking Calling the list of fixed value check weights for checkingFurther information English English Scales, System Solutions And Special Developments Soehnle Professional GmbH & Co. KGSoehnleDE-71522ProfessionalBacknangGmbH & Co. KG
Related manuals
Manual 36 pages 21.97 Kb

3030 specifications

The Soehnle 3030 is a high-quality digital bathroom scale designed to cater to the needs of health-conscious individuals looking for accurate weight measurements in the comfort of their homes. With its sleek, modern design and user-friendly features, it has gained widespread popularity in the fitness and wellness community.

One of the main features of the Soehnle 3030 is its advanced sensor technology, which ensures precise weight readings up to 180 kg (396 lbs). The scale is equipped with high-precision strain gauge sensors that provide reliable and consistent measurements every time. These sensors deliver an accuracy of 100 grams, allowing users to track their weight changes with confidence.

The scale's oversized LCD display is another notable characteristic. It is easy to read, showing weight measurements in large, clear digits, making it accessible for users of all ages. The display automatically turns on as soon as you step onto the scale, eliminating the need for manual activation. This smart feature adds to the convenience of using the Soehnle 3030.

In terms of design, the Soehnle 3030 boasts a contemporary look with a robust glass surface that not only enhances durability but also fits seamlessly into any bathroom decor. The scale's non-slip feet ensure stability while weighing, providing a safe and reliable experience.

The Soehnle 3030 also incorporates a user-friendly design that includes an automatic shutdown feature, conserving battery life when not in use. Increased functionality is a result of its ability to quickly switch between measurement units, with options for both kilograms and pounds.

Moreover, the scale is designed for easy maintenance, as a simple wipe with a damp cloth is enough to keep it looking pristine. The Soehnle 3030 combines style with practicality, making it an essential tool for anyone embarking on a weight management journey.

In summary, the Soehnle 3030 stands out in the market due to its high-precision measurement technology, user-friendly features, striking design, and reliable performance. It is a perfect choice for individuals who want an accurate, stylish, and functional scale that aligns with their health and wellness objectives. Whether starting a fitness journey or maintaining a healthy lifestyle, the Soehnle 3030 is an invaluable companion.