Soehnle 3030 New setpoint, Terminating the checking function, Fixed value memory for setpoints

Page 31

English

You can also display the difference between actual values and setpoint weights at the top left of the additional display in figures with a + or - sign. Activate the additional display by pressing F3 Unit in the Setting Functions level.

If you activated a memory location containing setpoints and tolerances in the Fixed Check memory, the special characters are activated automatically.

A totalising/batching operation (accept in the total memory by pressing the Plus key) interrupts the display of the quantity check special character until the scale is clipped off. The check special character is then reactivated.

Displaying the setpoint and tolerance

You can request the current setpoint used by pressing the key combination Info and F3 Setpoint.

New setpoint

Previous setpoints are overwritten with the new setpoint entered.

Terminating the checking function

Clear the stored setpoint to terminate the check operation and return to the weight display. Press F1 Setpoint in the Checking Functions level and then press the Clear key.

To change the program, press F5 Program in the Setting Functions level.

Fixed value memory for setpoints

You can store up to 400 setpoints in a failsafe memory.

Each memory location has:

-3-digit consecutive numbers

-description (plaintext 18 characters)

-article number (18 digits)

-reference weight

-reference quantity

-tolerance plus

-tolerance minus

a)Calling the list of check weight fixed values for editing Press the Info key and then F2 Check Fixed.

Selecting an existing fixed value from the list.

Browse using the arrow keys.

Call the required fixed value by pressing F6 Edit.

Editing an existing fixed value from the list

Call the marked fixed value for editing by pressing F6.

The Description parameter is marked. Call by pressing F6 Edit. Type in the value using the numerical/alphanumeric keypad. Accept the input by pressing F6.

(Clear the input without accepting by pressing F5 Cancel). You can edit other parameters in the same way.

Clearing an existing fixed value. Browse using the F3 and F4 arrow keys.

Clear the marked fixed value by pressing F6 Cancel. The gap in the consecutive number scheme is closed.

31

Image 31
Contents 3030 English ContentDescription of the appliance Technical dataOperating concept, keys and display symbols Installation and commissioningNavigation with the function keys Programming modeCancel Function keysDisplay Input and control keysSymbol for standstill Symbols in the display Symbol bar Information paneBasic functions Power on/offSelecting a program X10 display ZeroingGross display Organisation data identifiers Content inputDescription input Unit Switching between scalesManual switchover Automatic switchoverActivating input boxes Input procedure Numerical boxesAlphanumeric input Types of input boxSelecting an application program Application programsFunction keys Weighing and taringDisplay view Manual taring Weighing without taringTaring by manual tare input Automatic taring Multiplicative tareAdditive tare Provisional tareDisplay options with the Info key Error message when taring1st level totalising functions 3rd level setting functionsTotalising and batching Total memory with several connected scalesF5 Manual TaringOperating the totalising functions F6 PlusAssigning and clearing the consecutive number Clip off factor when totalisingSelection options for total display Automatic totalisingPrint keys Piece counterDisplaying the current totals Displaying individual pieces 2nd level checking functions 4th level setting functionsCounting 1st level counting functionsFunction key F2 Ref Variab Counting display viewCounting function Function key F1 RefFixed value memory for reference weights New reference weightDisplaying the reference weight Weight display during count operationQuantity check Calling the list of reference weights for countingTotalising different countable parts Data record/Printout within or outside the tolerance Switching points for quantity checkQuantity check special character Displaying the setpoint and tolerance Counting with several weighing platforms 1st level checking functions CheckingCheck special characters Check display viewChecking functions Type in setpointsTerminating the checking function New setpointFixed value memory for setpoints Switching points for checking Calling the list of fixed value check weights for checkingFurther information English English Soehnle Professional GmbH & Co. KG Scales, System Solutions And Special DevelopmentsSoehnleDE-71522ProfessionalBacknangGmbH & Co. KG