3M QuesTemp 32 user manual Electrical power research institute Epri, Light Moderate Heavy

Page 15

12

APPENDIX A: Heat Exposures Tables

Electrical power research institute (EPRI)

The recommended working hours are shown based on a maximum of four hours. A time of 4:01 indicates greater than 4 hours.

WBGT°C

Light

Moderate

Heavy

28

4:01

4:01

3:00

29

4:01

4:00

2:00

30

4:01

3:00

1:30

31

4:01

2:00

1:15

32

4:00

1:30

1:00

33

3:30

1:15

0:45

34

3:00

1:00

0:40

35

2:30

0:53

0:35

36

2:00

0:45

0:30

37

1:45

0:40

0:25

38

1:30

0:35

0:20

39

1:15

0:33

0:18

40

1:00

0:30

0:15

41

0:53

0:28

0

42

0:45

0:25

0

43

0:38

0:23

0

44

0:30

0:20

0

45

0:28

0:18

0

46

0:25

0:15

0

47

0:23

0

0

48

0:20

0

0

49

0:18

0

0

50

0:15

0

0

Image 15
Contents Market Leader Table of Contents Acgih Up and Running Check Wick and Fill Natural Wet BulbFilling wet bulb reservoir Heat Index / Humidex Wet Bulb Globe TemperatureMeasurements QUESTemp32Displayed Items Keypad OperationGlobe Thermometer Placement for monitoring/testingSensors Natural Wet Bulb ThermometerTri-Sensor Weighted Average Remote, Sensors 2Sensors 2 Relative Humidity Sensor Approved 9-Volt Batteries Power OptionsPower Options Alkaline Battery ReplacementBattery Pack NiMH Battery Pack Measurements SpecificationsNon-rechargeable battery Type Battery LifeAppendix a Heat Exposures Tables Appendix aUnited States Navy Wbgtf III Light Moderate Heavy Electrical power research institute EpriAppendix B Accessories Contacting 3M Detection Customer ServiceWarranty Service Department and Technical Support 1 800About Us