ACGIH

Screening Criteria for Heat Stress Exposure. WBGT values in °C.

NOTE: according to the ACGIH’s guidelines, the temperature values represent a work and rest process which is explained in the standards.

Please refer to the ACGIH TLV’s and BEIs for specific details.

 

Work and

 

Light

Moderate

Heavy

 

Very

 

 

 

 

 

 

recovery

 

 

 

 

 

Heavy

 

 

(TLV )

 

 

 

 

 

 

 

75% to 100%

 

31.0

28.0

26.0*

23.5*

 

50% to 75%

 

31.0

29.0

27.5

25.5*

 

25% to 50%

 

32.0

30.0

29.0

28.0

 

0% to 25%

 

32.5

31.5

30.5

30.0

 

Work and

 

Light

 

Moderate

 

Heavy

 

Very

recovery

 

 

 

 

 

 

 

Heavy

(Action Limit)

 

 

 

 

 

 

 

 

75% to 100%

28.0

25.0

22.5*

20.0*

50% to 75%

28.5

26.0

24.0

22.5*

25% to 50%

29.5

27.0

25.5

24.5

0% to 25%

30.0

29.0

28.0

27.0

*Values not specified by ACGIH have been estimated for continuity.

Cited from "American Conference of Governmental Industrial Hygienists - Threshold Limit Values and Biological Exposure Indices for 2008"; Reprinted with permission from ACGIH

United States Navy

Physiological Heat Exposure Limits (PHEL) Time Table (Without the presence of fuel combustion gases/fuel vapors) is displayed on the following page.

The recommended working hours are shown based on a maximum of eight hours. Naval personnel will follow a category, I - VI, based upon their function.

Image 13
Contents Market Leader Table of Contents Acgih Check Wick and Fill Natural Wet Bulb Up and RunningFilling wet bulb reservoir Measurements Wet Bulb Globe TemperatureQUESTemp32 Heat Index / HumidexDisplayed Items Keypad OperationSensors Placement for monitoring/testingNatural Wet Bulb Thermometer Globe ThermometerRemote, Sensors 2 Tri-Sensor Weighted AverageSensors 2 Relative Humidity Sensor Power Options Power OptionsAlkaline Battery Replacement Approved 9-Volt BatteriesBattery Pack NiMH Battery Pack Measurements SpecificationsNon-rechargeable battery Type Battery LifeAppendix a Appendix a Heat Exposures TablesUnited States Navy Wbgtf III Light Moderate Heavy Electrical power research institute EpriAppendix B Accessories Warranty Customer ServiceService Department and Technical Support 1 800 Contacting 3M DetectionAbout Us