Parker Products COMPAX-M /-S (L) manual P25 Advance, Speed control, Advance speed control

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 130
Image 130

Operating Instructions

COMPAX-M / -S

Optimization parameters

P25: Advance

Advance speed control

speed control:

Nominal value: 100% Range: 0%...500%

reference

value,1 actual value

2

t

Driving fault, current

3

4

t

1:Nominal speed value

2:Actual speed value

3:Motor power

4:Lag error

P26: Advance acceleration control

P70: Advance power control

Advance speed and acceleration control Nominal value: 100% Range: 0%...500%

reference

value,1 actual value

2

t

Driving fault, current

3

4

t

Advance speed, acceleration and power control Nominal value: 100% Range: 0%...500%

 

2

reference

 

value,

1

actual

 

value

 

t

Driving fault, current

3

4

t

1:Nominal speed value

2:Actual speed value

3:Motor power

4:Lag error

1:Nominal speed value

2:Actual speed value

3:Motor power

4:Lag error

Advance reverse The advance reverse control can be engaged to increase optimization of guide

controlcharacteristics and reduce dynamic lag error by using P69. Nominal value: 100% Range: 0 ... 500% default value: 0; applies to VP