Parker Products COMPAX-M /-S (L) manual Stop / Break handling if Stop Gosub, Error program with

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 111
Image 111

Positioning and control functions

Unit hardware

Error program with

WAIT START

STOP / BREAK handling [IF STOP GOSUB xxx]

and is used to bring the individual outputs (e.g. the control output for a pump or a valve) into a safe status.

Each error program must contain a 'WAIT START' instruction.

The 'WAIT START' instruction causes the programming procedure to stop until an external QUIT and START occurs.

Then OUTPUT instructions can again be present for resetting the outputs. There must be a RETURN or END instruction at the end of the error program.

The END instruction stops the program.

The RETURN instruction executes a jump back into the program line which was previously interrupted. If necessary, an interrupted movement is continued (provided that the error has been acknowledged).

Connector

assignment / cable

Technical data

 

Example: Main Program

Error Program

N001: IF ERROR GOSUB 200

N200: OUTPUT O9=0

N002: OUTPUT O9=1

N201: WAIT START

N003: POSA 0

N202: OUTPUT O9=1

N004: POSA 4000

N203: RETURN

N005: OUTPUT O9=0

 

N006: GOTO 002

 

If the axis is now stopped and switched off due to an error, e.g. during POSA 4000 positioning, a sub-program jump is then executed to program line 200 and output O9 is set to zero at this point.

The program then stops in program line 201 and waits until the error has been acknowledged and, if necessary, a new start is made.

At program line 202, output O9 is switched on again, at program line 203, a jump is made back to the previously interrupted program line N004.

The axis executes the rest of the travel to position 4000, and the main program is then continued at program line N005.

If the error program is concluded with END rather than RETURN, the program indicator remains in the same position. The program stops running at this point. Machine zero then has to approached or the program indicator must be reset explicity.

8.4.29 STOP / BREAK handling [IF STOP GOSUB xxx]

Configuration

 

Positioning and

control functions

Optimization

functions

Interfaces

 

/

 

IF STOP GOSUB xxx

Syntax:

For influencing behavior after STOP or BREAK.

IF STOP GOSUB xxx

This instruction can only be programmed, like normal IF instructions, in the program. It controls the procedure executed in the program when a stop status occurs.

Normally, a STOP / BREAK command in the COMPAX will cause a actively running move to be interrupted; the program is stopped.

The 'IF STOP GOSUB xxx' instruction makes it possible to set the outputs to defined states in a stopped condition.

If such an instruction has already run in the program and a stop command occurs later:

the current travel motion is interrupted and then

a 'Stop program' is run, this is stored from program line number xxx.