Parker Products COMPAX-M /-S (L) manual Digital inputs and outputs Example

Models: COMPAX-M /-S (L)

1 242
Download 242 pages 31.85 Kb
Page 141
Image 141

Interfaces

Digital inputs and outputs

Example:

Unit hardware

 

cable

The following assignment must be configured:

"0"

input 1

X19 pin 3

input 2

X19 pin 4

input 3

X19 pin 5

input 4

X19 pin 6

input 5

X19 pin 7

input 6

"0"

input 7

"0"

input 8

"0"

input 9

"0"

input 10

"0"

input 11

X19 pin 8

input 12

X19 pin 2

input 13

"1"

input 14

"0"

input 15

X19 pin 9

input 16

 

 

 

 

 

Source

 

 

 

 

factor

computed values

Allocation:

Logical

 

 

fixed logical value (0 or 1) or pin of X19

 

 

 

 

Input reads from

inputs

 

=0

=1

/2

/3

/4

/5

/6

/7

/8

/9

 

 

 

which source

 

Wert:

0

1

2

3

4

5

6

7

8

9

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

1

 

0*1=0

P156 bit 0...3

Input 1

 

 

 

 

x

 

 

 

 

 

 

16

+

3*16=48

P156 bit 4...7

Input 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

 

256

+

4*256=1024

P156 bit 8...11

Input 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

4096

+

5*4096=20480

P156 bit 12...15

Input 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

65536

+

6*65536= 393216

P156 bit 16...19

Input 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

1048576

+

7*1048576=7340032

P156 bit 20...23

Input 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Σ

7 754 800

Total 8 388 607

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P156 = Total

 

 

 

 

 

 

 

 

 

 

 

Value of P156:

 

7 754 800

 

 

 

 

 

 

 

 

 

 

 

 

Total > 8 388 607

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P156 = Total – 16 777 216

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

1

 

0*1=0

P157 bit 0...3

Input 7

 

x

 

 

 

 

 

 

 

 

 

16

+

0*16=0

P157 bit 4...7

Input 8

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

256

+

0*256=0

P157 bit 8...11

Input 9

 

x

 

 

 

 

 

 

 

 

 

4096

+

0*4096=0

P157 bit 12...15

Input 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

65536

+

0*65536=0

P157 bit 16...19

Input 11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

1048576

+

8*1048576=8388608

P157 bit 20...23

Input 12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Σ

8 388 608

Total 8 388 607

 

 

 

 

 

 

 

 

 

 

 

Value of P157:

 

 

P156 = Total

 

 

 

 

 

 

 

 

 

 

 

 

-8 388 608

Total > 8 388 607

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P156 = Total – 16 777 216

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

1

 

2*1=2

P158 bit 0...3

Input 13

 

 

x

 

 

 

 

 

 

 

 

16

+

1*16=16

P158 bit 4...7

Input 14

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

256

+

0*256=0

P158 bit 8...11

Input 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

4096

+

9*4096=36 864

P158 bit 12...15

Input 16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Value of P158:

Σ

36 882

 

 

Connector

assignment /

Technical data

 

 

 

Configuration

 

 

 

Positioningand

controlfunctions

The remaining inputs stay open and are therefore not imported.

You can see the calculation of the setting values on the right.

Note

It is in principle possible to read 2 inputs from the same input pin. Of course note should be taken of the resulting function.

If you do not need the enable input I12, fixed logic "1" can be allocated.

With P233=49 (or P234=49), physical inputs pin 9 – pin 2 are written to the optimization display status S13 (S14). Meaning: pin 2 = bit 0 ... pin 9 = bit 7.

141

Optimization

functions

 

 

Interfaces

 

 

 

Accessories /

options

 

 

Status

 

 

 

Parameter

 

 

 

Error list

 

 

 

Page 141
Image 141
Parker  Products COMPAX-M /-S (L) manual Digital inputs and outputs Example